- SUBROUTINE DEALLOCATE_ARRAYS_CHOKE()
-
- USE CHOKEVARIABLES
- implicit none
- write(*,*) 'deallocateeeeeeeeeeeee'
- !===========================================================================
- ! AIR PUMP LOSSES INPUT
- !===========================================================================
- !if(allocated(PIPINGS_AIRPUMP)) deallocate(PIPINGS_AIRPUMP)
-
- DEALLOCATE (AirPumpLine%PIPINGS_AIRPUMP,AirPumpLine%DIAM_AIR_INCH, &
- AirPumpLine%Re_air,AirPumpLine%AREA_AIR,AirPumpLine%LENGT_AIR,AirPumpLine%ROUGHNESS_AIRPLINE,AirPumpLine%REL_ROUGHAIR, &
- AirPumpLine%fric_air,AirPumpLine%fricloss_air)
- !================================================================
- DEALLOCATE (AirPumpLine%MINORS_AIRPUMP,AirPumpLine%MINORDIAM_AIR_INCH, &
- AirPumpLine%MINORAREA_AIR,AirPumpLine%LF_AIR,AirPumpLine%CV_AIR,AirPumpLine%NOTE_AIR &
- ,AirPumpLine%minlosspa_air,AirPumpLine%minloss_air)
-
- END
-
-
-
-
-
-
- SUBROUTINE LOSS_INPUTS_CHOKE()
- USE CHOKEVARIABLES
- implicit none
- Integer I
-
-
- !===========================================================================
- ! AIR PUMP LOSSES INPUT
- !===========================================================================
- AirPumpLine%NO_PIPINGS_AIRPLINE=1
-
- ALLOCATE (AirPumpLine%PIPINGS_AIRPUMP(AirPumpLine%NO_PIPINGS_AIRPLINE,3))
- ! ID(INCH) L(MM) ROUGHNESS(MM)=e DESCRIPTION
- AirPumpLine%PIPINGS_AIRPUMP(1,1:3)= (/0.5, 60960., 0.03/) !Avg.acc.distance
-
- !60960= 200 ft
-
-
- ALLOCATE (AirPumpLine%DIAM_AIR_INCH(AirPumpLine%NO_PIPINGS_AIRPLINE),AirPumpLine%Re_air(AirPumpLine%NO_PIPINGS_AIRPLINE),AirPumpLine%AREA_AIR(AirPumpLine%NO_PIPINGS_AIRPLINE), &
- AirPumpLine%LENGT_AIR(AirPumpLine%NO_PIPINGS_AIRPLINE),AirPumpLine%ROUGHNESS_AIRPLINE(AirPumpLine%NO_PIPINGS_AIRPLINE),AirPumpLine%REL_ROUGHAIR(AirPumpLine%NO_PIPINGS_AIRPLINE), &
- AirPumpLine%fric_air(AirPumpLine%NO_PIPINGS_AIRPLINE),AirPumpLine%fricloss_air(AirPumpLine%NO_PIPINGS_AIRPLINE))
-
-
-
- DO I=1,AirPumpLine%NO_PIPINGS_AIRPLINE
- AirPumpLine%DIAM_AIR_INCH(I)=AirPumpLine%PIPINGS_AIRPUMP(I,1)
- AirPumpLine%LENGT_AIR(I)=AirPumpLine%PIPINGS_AIRPUMP(I,2)
- AirPumpLine%ROUGHNESS_AIRPLINE(I)=AirPumpLine%PIPINGS_AIRPUMP(I,3)
-
-
- AirPumpLine%AREA_AIR(I)=PI*(AirPumpLine%DIAM_AIR_INCH(I)*0.0254)**2/4 !D(in), AREA(m)
- AirPumpLine%REL_ROUGHAIR(I)=AirPumpLine%ROUGHNESS_AIRPLINE(I)/(AirPumpLine%DIAM_AIR_INCH(I)*25.4)
- !DIAM_RAMLINE_MM(I)=DIAM_RAMLINE_MM(I)*.001 ! (m)
- AirPumpLine%LENGT_AIR(I)=AirPumpLine%LENGT_AIR(I)*.001 ! (m)
- ENDDO
-
-
- !================================================================
- AirPumpLine%NO_MINORS_AIRPLINE=6
-
- ALLOCATE (AirPumpLine%MINORS_AIRPUMP(AirPumpLine%NO_MINORS_AIRPLINE,4))
-
- ! ID(INCH) LF CV NOTE(BAR) DESCRIPTION
- AirPumpLine%MINORS_AIRPUMP(1,1:4)= (/2., 10., 0., 0./) !Acc.tee
- AirPumpLine%MINORS_AIRPUMP(2,1:4)= (/2., 11., 0., 0./) !elbow
- AirPumpLine%MINORS_AIRPUMP(3,1:4)= (/1., 0., 0., 3.4/) !filter
- AirPumpLine%MINORS_AIRPUMP(4,1:4)= (/2., 0., 105., 0./) !valve
- AirPumpLine%MINORS_AIRPUMP(5,1:4)= (/1., 0., 9.2, 0./) !valve
- AirPumpLine%MINORS_AIRPUMP(6,1:4)= (/2., 6.4, 0., 0./) !unionA
-
-
-
- ALLOCATE (AirPumpLine%MINORDIAM_AIR_INCH(AirPumpLine%NO_MINORS_AIRPLINE),AirPumpLine%MINORAREA_AIR(AirPumpLine%NO_MINORS_AIRPLINE), &
- AirPumpLine%LF_AIR(AirPumpLine%NO_MINORS_AIRPLINE),AirPumpLine%CV_AIR(AirPumpLine%NO_MINORS_AIRPLINE),AirPumpLine%NOTE_AIR(AirPumpLine%NO_MINORS_AIRPLINE) &
- ,AirPumpLine%minlosspa_air(AirPumpLine%NO_MINORS_AIRPLINE),AirPumpLine%minloss_air(AirPumpLine%NO_MINORS_AIRPLINE))
-
-
-
- DO I=1,AirPumpLine%NO_MINORS_AIRPLINE
- AirPumpLine%MINORDIAM_AIR_INCH(I)=AirPumpLine%MINORS_AIRPUMP(I,1)
- AirPumpLine%LF_AIR(I)=AirPumpLine%MINORS_AIRPUMP(I,2)
- AirPumpLine%CV_AIR(I)=AirPumpLine%MINORS_AIRPUMP(I,3)
- AirPumpLine%NOTE_AIR(I)=AirPumpLine%MINORS_AIRPUMP(I,4)
-
-
- AirPumpLine%MINORAREA_AIR(I)=PI*(AirPumpLine%MINORDIAM_AIR_INCH(I)*0.0254)**2/4. !D(in), AREA(m)
- ENDDO
-
-
- END
-
-
-
-
-
- SUBROUTINE PIPE_RAMS_CHOKE(CHNUMBER)
- USE CHOKEVARIABLES
- Use CSimulationVariables
- implicit none
- INTEGER CHNUMBER
- Integer I
-
-
- loop3: do while (ABS(ChokeControlPanel%ChokeControlLever)==1.0 .AND. ChokeControlPanel%ChokePanelRigAirSwitch == 1 .AND. CHOOKE(CHNUMBER)%FailMalf==0 .AND. AirDrivenPump%ChokeAirFail==0)
- if (ChokeControlPanel%ChokeControlLever == 1.0) then
- CHOOKE(CHNUMBER)%ChokeIsClosing = .true.
- CHOOKE(CHNUMBER)%ChokeIsOpening = .false.
- endif
-
- if (ChokeControlPanel%ChokeControlLever == -1.0) then
- CHOOKE(CHNUMBER)%ChokeIsOpening = .true.
- CHOOKE(CHNUMBER)%ChokeIsClosing = .false.
- endif
-
-
-
- AirPumpLine%TIME=AirPumpLine%TIME+AirPumpLine%DeltaT_Choke !overal time (s)
-
-
-
- !====================================================
- ! ********************************
- call airpump_code_CHOKE(CHNUMBER)
- ! *************************
- !====================================================
-
- call sleepqq(100)
-
-
- if (IsStopped == .true.) return
-
- end do loop3 !while finished_Choke==0
-
- end
-
-
-
-
-
-
- SUBROUTINE airpump_code_CHOKE(CHNUMBER)
- USE CHOKEVARIABLES
- USE CChokeManifoldVariables
- use CSounds
- USE CChokeProblemsVariables
- implicit none
- Integer I
-
- INTEGER CHNUMBER
-
-
- AirDrivenPump%QAIR_PUMP=AirPumpLine%QITER+.1 !(gpm) maximum flow for the start
- AirPumpLine%diffp_air=-10
- AirPumpLine%losses_air=10
-
- !===================================================================
- ! AIR OPERATED PUMP
- ! MODEL 10-6000W030 RATIO 55:1
- !=================for air consumption at 100 psig===================
- do while (AirPumpLine%diffp_air<0)
- AirDrivenPump%QAIR_PUMP=AirDrivenPump%QAIR_PUMP-.1
- ! Qup=AirDrivenPump%QAIR_PUMP;
- !cc1 = 1354; cc2 = -2066; cc3 = -2109; cc4 = -513.6; cc5 = 5935 FOR OUTPUT IN GPM
- AirPumpLine%P_AIRP=AirDrivenPump%cc1*(AirDrivenPump%QAIR_PUMP**4) + AirDrivenPump%cc2*(AirDrivenPump%QAIR_PUMP**3) + AirDrivenPump%cc3*(AirDrivenPump%QAIR_PUMP**2) + AirDrivenPump%cc4*AirDrivenPump%QAIR_PUMP + AirDrivenPump%cc5 !(psig)
- ! kinetic_air=sg*wdens*(QAIR_PUMP*6.30902e-5/((1/4.)*pi*(2*0.254e-1)**2))**2/(2*6895) !(psi)
-
- AirPumpLine%diffp_air= AirPumpLine%P_AIRP - AirPumpLine%Pdownstrem
-
- end do !returns Qup
-
-
-
- do while (abs((AirPumpLine%diffp_air-AirPumpLine%losses_air)/AirPumpLine%diffp_air)>AirPumpLine%TOL_AIR) !finding correct QAIR_pump for 1 timecounter_ram
-
- if (AirPumpLine%diffp_air-AirPumpLine%losses_air>0) then
- AirDrivenPump%QAIR_PUMP=AirDrivenPump%QAIR_PUMP+.005
- else
- AirDrivenPump%QAIR_PUMP=AirDrivenPump%QAIR_PUMP-.005
- endif
-
- !===================================================================
- ! AIR OPERATED PUMP
- ! MODEL 10-6000W030 RATIO 55:1
- !=================for air consumption at 100 psig===================
-
- AirPumpLine%P_AIRP=AirDrivenPump%cc1*(AirDrivenPump%QAIR_PUMP**4) + AirDrivenPump%cc2*(AirDrivenPump%QAIR_PUMP**3) + AirDrivenPump%cc3*(AirDrivenPump%QAIR_PUMP**2) + AirDrivenPump%cc4*AirDrivenPump%QAIR_PUMP + AirDrivenPump%cc5 !(psig)
- !kinetic_air=sg*wdens*(QAIR_PUMP*6.30902e-005/((1/4.)*pi*(2*0.254e-1)**2))**2/(2*6895) !(psi)
-
- AirPumpLine%diffp_air= AirPumpLine%P_AIRP - AirPumpLine%Pdownstrem
-
-
- !===========================LOSSES====================================
- do i=1,AirPumpLine%NO_PIPINGS_AIRPLINE
- AirPumpLine%Re_air(i)=AirDrivenPump%QAIR_PUMP*6.30902e-005*AirPumpLine%DIAM_AIR_INCH(I)*0.0254/(AirPumpLine%AREA_AIR(i)*nu)
- enddo
-
-
- do i=1,AirPumpLine%NO_PIPINGS_AIRPLINE
- if (AirPumpLine%Re_air(i)<Re_cr) then
- AirPumpLine%fric_air(i)=64/AirPumpLine%Re_air(i)
- else
- AirPumpLine%fric_air(i)=1/(-1.8*log10((AirPumpLine%REL_ROUGHAIR(i)/3.7)**1.11+6.9/AirPumpLine%Re_air(i)))**2
- endif
-
- AirPumpLine%fricloss_air(i)=((AirPumpLine%fric_air(i)*(wdens*sg*AirPumpLine%LENGT_AIR(i)*(AirDrivenPump%QAIR_PUMP*6.30902e-005/AirPumpLine%AREA_AIR(i))**2))/(2*AirPumpLine%DIAM_AIR_INCH(I)*0.0254))/6895
-
- enddo
-
-
-
-
- AirPumpLine%pipe_loss1air=sum(AirPumpLine%fricloss_air) !loss before regulator(psi)
-
- do i=1,AirPumpLine%NO_MINORS_AIRPLINE
- if (AirPumpLine%LF_AIR(i)/=0) then
- AirPumpLine%minlosspa_air(i)=AirPumpLine%LF_AIR(i)*wdens*sg*(AirDrivenPump%QAIR_PUMP*6.30902e-005/AirPumpLine%MINORAREA_AIR(i))**2/2 !(Pa)
- AirPumpLine%minloss_air(i)=AirPumpLine%minlosspa_air(i)/6895 !(psi)
- elseif (AirPumpLine%CV_AIR(i)/=0) then
- AirPumpLine%minlosspa_air(i)=1000*sg*((11.7*AirDrivenPump%QAIR_PUMP*6.30902e-005*3600)/(AirPumpLine%CV_AIR(i)))**2 !(pa)
- AirPumpLine%minloss_air(i)=AirPumpLine%minlosspa_air(i)/6895 !(psi)
- else
- AirPumpLine%minlosspa_air(i)=AirPumpLine%NOTE_AIR(i)*1e5 !(pa)
- AirPumpLine%minloss_air(i)=AirPumpLine%minlosspa_air(i)/6895 !(psi)
- endif
- enddo
-
-
- AirPumpLine%minor_loss1air=sum(AirPumpLine%minloss_air) !loss before regulator(psi)
-
- AirPumpLine%static_loss1air=0
-
- AirPumpLine%losses_air=AirPumpLine%pipe_loss1air+AirPumpLine%minor_loss1air+AirPumpLine%static_loss1air !(psi)
- !=========================================================================
-
-
- end do !returns correct QAIR_PUMP for 1 counter
-
-
-
-
- AirPumpLine%QITER=AirDrivenPump%QAIR_PUMP
- AirDrivenPump%QAIR_PUMP=AirDrivenPump%QAIR_PUMP*(ChokeControlPanel%ChokeRateControlKnob/10.) ! final Q (gpm)
-
- Choke%Cumulative_AirVolume_Choke= Choke%Cumulative_AirVolume_Choke + ((AirDrivenPump%QAIR_PUMP * AirPumpLine%DeltaT_Choke / 60.0 ) / (1.5*0.004329004) ) ! =strokes
-
-
- if ( Choke%Cumulative_AirVolume_Choke > 1.0 ) then
- Choke%SoundChokePump= 60
- Choke%Cumulative_AirVolume_Choke= Choke%Cumulative_AirVolume_Choke - 1.0
- else
- Choke%SoundChokePump= 0.0
- endif
-
- !SoundChokePump= int (QAIR_PUMP/ (1.5*0.004329004)*DeltaT_Choke/60.0) ! 1.5: Volume per stroke (in^3) , 0.004329004: in^3 to gal , 60:seconds
-
-
-
- AirPumpLine%DELTAV_AIR=AirDrivenPump%QAIR_PUMP*AirPumpLine%DeltaT_Choke/60 !(galon) delta_t=1sec , Q(gpm)
-
- if (CHOOKE(CHNUMBER)%ChokeIsClosing) CHOOKE(CHNUMBER)%PassedCourse=CHOOKE(CHNUMBER)%PassedCourse + (AirPumpLine%DELTAV_AIR*3785.412/AirPumpLine%Acylinder)!*(ChokeRateControlKnob/10.) ! 3785.412 : GALON TO CM^3
-
-
- if (CHOOKE(CHNUMBER)%ChokeIsOpening) CHOOKE(CHNUMBER)%PassedCourse=CHOOKE(CHNUMBER)%PassedCourse - (AirPumpLine%DELTAV_AIR*3785.412/AirPumpLine%Acylinder)!*(ChokeRateControlKnob/10.)
-
-
-
- !DeltaT_Choke= 1sec or 2sec
-
-
- !((((((((IN OUTER LOOP))))))
-
- !===============AIR PUMP OUTPUTS=========================
- AirPumpLine%alpha_timeair=AirPumpLine%TIME ! overal time (s)
- AirPumpLine%alpha_Pdownstrem=AirPumpLine%Pdownstrem
- AirPumpLine%alpha_pairp=AirPumpLine%P_AIRP
- AirPumpLine%alpha_Qair=AirDrivenPump%QAIR_PUMP
- !write(*,*) 'diffp_air=',diffp_air
- !pause
- AirPumpLine%alpha_diffpair=AirPumpLine%diffp_air
-
- AirPumpLine%alpha_lossesair=AirPumpLine%losses_air
- !========================================================
- !OPEN(150,FILE='CHOKE_AIRPUMP_OUTPUTS.DAT')
-
-
- if (CHOOKE(CHNUMBER)%ChokeIsClosing .AND. CHOOKE(CHNUMBER)%PassedCourse>AirPumpLine%CourseBase) then
- CHOOKE(CHNUMBER)%PassedCourse=AirPumpLine%CourseBase
- Choke%SoundChokePump= 0.0
- endif
-
- if (CHOOKE(CHNUMBER)%ChokeIsOpening .AND. CHOOKE(CHNUMBER)%PassedCourse<0.) then
- CHOOKE(CHNUMBER)%PassedCourse=0.
- Choke%SoundChokePump= 0.0
- endif
-
-
- call SetSoundChokePump(Choke%SoundChokePump)
-
- CHOOKE(CHNUMBER)%PercentClose= CHOOKE(CHNUMBER)%PassedCourse/AirPumpLine%CourseBase
-
-
- IF (ChokeControlPanel%Choke1LED==1) THEN
- ChokeControlPanel%ChokePosition= (1 - Choke%GaugeChokePositionMailf) * CHOOKE(1)%PercentClose*10
- ELSE ! Choke2LED==1
- ChokeControlPanel%ChokePosition= (1 - Choke%GaugeChokePositionMailf) * CHOOKE(2)%PercentClose*10
- ENDIF
-
- !CALL SetHydraulicChock1(nint(MIN(CHOOKE(1)%PercentClose / 0.91 , 1.0)*100))
- ! CALL SetHydraulicChock2(nint(MIN(CHOOKE(2)%PercentClose / 0.91 , 1.0)*100))
-
- ! .91 >> 9 percent clearance
-
- ! =================== calculating Area
-
- ! AreaChoke=0.5
- ! .91 >> 9 percent clearance
-
- CHOOKE(1)%AreaChoke=0.01334635-(0.01334635* MIN(CHOOKE(1)%PercentClose / 0.91 , 1.0)) !ft^2 0.01334635 is ChokeAreaFullyOpen (ft^2)
- CHOOKE(2)%AreaChoke=0.01334635-(0.01334635* MIN(CHOOKE(2)%PercentClose/ 0.91 , 1.0)) !ft^2
-
- !write(*,*) 'CHOOKE(1)%AreaChoke= ' , CHOOKE(1)%AreaChoke
-
-
-
-
- Choke%HydraulicChoke1WashoutCoef= Choke%HydraulicChoke1WashoutCoef * CHOOKE(1)%WashoutMalf
- Choke%HydraulicChoke1WashoutCoef= MIN( 0.5 , Choke%HydraulicChoke1WashoutCoef+ CHOOKE(1)%WashoutMalf*(0.5/(60.0/AirPumpLine%DeltaT_Choke)) ) ! 0.5=maximum washout coef , 60.0 sec= 1min duration time
-
- Choke%HydraulicChoke2WashoutCoef= Choke%HydraulicChoke2WashoutCoef * CHOOKE(2)%WashoutMalf
- Choke%HydraulicChoke2WashoutCoef= MIN( 0.5 , Choke%HydraulicChoke2WashoutCoef+ CHOOKE(2)%WashoutMalf*(0.5/(60.0/AirPumpLine%DeltaT_Choke)) ) ! 0.5=maximum washout coef , 60.0 sec= 1min duration time
-
-
- !write(*,*) 'HydraulicChoke1WashoutCoef=' , HydraulicChoke1WashoutCoef
-
- IF (CHOOKE(1)%PlugMalf == 1) THEN
-
- Choke%Present_HydraulicChoke1Plug= Choke%Present_HydraulicChoke1Plug * CHOOKE(1)%PlugMalf
- ! integer: HydraulicChoke1PluggedPercent,HydraulicChoke1PluggedPercent_Old,PlugTimeCounter,ChokePlugTimeDelay
- ! real: Present_HydraulicChoke1Plug,DeltaPlug1Percent
-
- !write(*,*) 'HydraulicChoke1PluggedPercent=' , HydraulicChoke1PluggedPercent
-
- if ( (ChokeProblems%HydraulicChoke1PluggedPercent - Choke%HydraulicChoke1PluggedPercent_Old) /= 0) then
- Choke%DeltaPlug1Percent = (REAL(ChokeProblems%HydraulicChoke1PluggedPercent)/100.) - Choke%Present_HydraulicChoke1Plug
- Choke%Plug1TimeCounter = 0
- !write(*,*) 'DeltaPlug1Percent, Present_HydraulicChoke1Plug = ' ,DeltaPlug1Percent , Present_HydraulicChoke1Plug
- endif
-
-
- Choke%Plug1TimeCounter= Choke%Plug1TimeCounter + 1
-
- Choke%HydraulicChoke1PluggedPercent_Old= ChokeProblems%HydraulicChoke1PluggedPercent
-
- if (Choke%Plug1TimeCounter <= Choke%ChokePlugTimeDelay) then !ChokePlugTimeDelay=600
-
- Choke%Present_HydraulicChoke1Plug = Choke%Present_HydraulicChoke1Plug + CHOOKE(1)%PlugMalf* ((Choke%DeltaPlug1Percent / real(Choke%ChokePlugTimeDelay))) ! real(ChokePlugTimeDelay)= 600.0
-
- endif
-
- !write(*,*) 'Present_HydraulicChoke1Plug=' , Present_HydraulicChoke1Plug
-
- ENDIF
-
-
-
-
-
-
- IF (CHOOKE(2)%PlugMalf == 1) THEN
-
- Choke%Present_HydraulicChoke2Plug= Choke%Present_HydraulicChoke2Plug * CHOOKE(2)%PlugMalf
- ! integer: HydraulicChoke2PluggedPercent,HydraulicChoke2PluggedPercent_Old,PlugTimeCounter,ChokePlugTimeDelay
- ! real: Present_HydraulicChoke2Plug,DeltaPlug2Percent
-
-
- if ( (ChokeProblems%HydraulicChoke2PluggedPercent - Choke%HydraulicChoke2PluggedPercent_Old) /= 0 ) then
- Choke%DeltaPlug2Percent = (REAL(ChokeProblems%HydraulicChoke2PluggedPercent)/100.) - Choke%Present_HydraulicChoke2Plug
- Choke%Plug2TimeCounter = 0
- endif
-
- Choke%Plug2TimeCounter= Choke%Plug2TimeCounter + 1
-
- Choke%HydraulicChoke2PluggedPercent_Old= ChokeProblems%HydraulicChoke2PluggedPercent
-
- if (Choke%Plug2TimeCounter <= Choke%ChokePlugTimeDelay) then !ChokePlugTimeDelay=600
-
- Choke%Present_HydraulicChoke2Plug = Choke%Present_HydraulicChoke2Plug + CHOOKE(2)%PlugMalf *((Choke%DeltaPlug2Percent / real(Choke%ChokePlugTimeDelay))) ! real(ChokePlugTimeDelay)= 600.0
-
- endif
-
- ENDIF
-
-
-
-
-
-
-
- ! fully open area is 123/64 in^2 = 0.01334635 ft^2
- CHOOKE(1)%AreaChoke=CHOOKE(1)%AreaChoke+(CHOOKE(1)%WashoutMalf*Choke%HydraulicChoke1WashoutCoef*Choke%ChokeAreaFullyOpen/144.0) ! Initialised in Choke Startup
-
- !write(*,*) 'CHOOKE(1)%WashoutMalf , CHOOKE(1)%AreaChoke=' ,CHOOKE(1)%WashoutMalf , CHOOKE(1)%AreaChoke
-
- CHOOKE(1)%AreaChoke=CHOOKE(1)%AreaChoke-(CHOOKE(1)%PlugMalf* Choke%Present_HydraulicChoke1Plug *CHOOKE(1)%AreaChoke) ! Initialised in Choke Startup
-
- CHOOKE(2)%AreaChoke=CHOOKE(2)%AreaChoke+(CHOOKE(2)%WashoutMalf*Choke%HydraulicChoke2WashoutCoef*Choke%ChokeAreaFullyOpen/144.0) ! Initialised in Choke Startup
- CHOOKE(2)%AreaChoke=CHOOKE(2)%AreaChoke-(CHOOKE(2)%PlugMalf* Choke%Present_HydraulicChoke2Plug *CHOOKE(2)%AreaChoke) ! Initialised in Choke Startup
- !write(*,*) 'CHOOKE(2)%WashoutMalf , CHOOKE(2)%AreaChoke=' ,CHOOKE(2)%WashoutMalf , CHOOKE(2)%AreaChoke
-
-
- CHOOKE(1)%AreaChokeFinal= CHOOKE(1)%AreaChoke
- CHOOKE(2)%AreaChokeFinal= CHOOKE(2)%AreaChoke
-
- ! 144: ft^2 to in^2
- CALL SetHydraulicChock1(100 - nint((CHOOKE(1)%AreaChokeFinal/(Choke%ChokeAreaFullyOpen/144.))*100)) ! for manifold valve
- CALL SetHydraulicChock2(100 - nint((CHOOKE(2)%AreaChokeFinal/(Choke%ChokeAreaFullyOpen/144.))*100)) ! for manifold valve
-
-
- !write(*,*) 'CHOOKE(1)%PercentClose=' , CHOOKE(1)%PercentClose ! close percent 0 to 100
- !write(*,*) 'ChokePosition=' , ChokePosition ! close position 0 to 10 for display
- !write(*,*) 'CHOOKE(1)%AreaChokeFinal=' , CHOOKE(1)%AreaChokeFinal ! Open Area (in^2) with clearance
- !write(*,*) '(ChokeAreaFullyOpen/144.)=' , (ChokeAreaFullyOpen/144.)
- !write(*,*) 'valve value=' , 100 - nint((CHOOKE(1)%AreaChokeFinal/(ChokeAreaFullyOpen/144.))*100) ! percent close 0 to 100 with clearance
- !write(*,*) 'Valve(33)%Status=' , Valve(33)%Status ! T : open , F: close
-
-
-
-
-
- ! =================== calculating Area
-
-
-
- !write(*,*) 'CHOOKE(1)%AreaChoke= ' , CHOOKE(1)%AreaChoke
-
-
-
- ! WRITE(150,50) alpha_timeair,alpha_Qair,alpha_pairp, &
- ! alpha_Pdownstrem,alpha_diffpair,alpha_lossesair,CHOOKE(CHNUMBER)%PassedCourse
- !50 FORMAT(7(f15.5))
-
-
- !========================================================================================
- !========================================================================================
-
- ! write(*,*) PassedCourse
-
-
-
- end
|