- module PumpsMain
-
- use CPumpsVariables
- use CDrillingConsoleVariables
- use CDataDisplayConsoleVariables
- use CSimulationVariables
- use Pump_VARIABLES
- use CSounds
-
- implicit none
- public
-
- contains
-
-
-
- ! ****************************************
- ! ***** subroutine Pump1MainBody *****
- ! ****************************
-
- subroutine Pump1_Setup()
- use CSimulationVariables
- implicit none
- call OnSimulationInitialization%Add(Pump1_Init)
- call OnSimulationStop%Add(Pump1_Init)
- call OnPump1Step%Add(Pump1_Step)
- call OnPump1Output%Add(Pump1_Output)
- call OnPump1Main%Add(Pump1MainBody)
- end subroutine
-
- subroutine Pump1_Init
- Call Pump_StartUp
- end subroutine Pump1_Init
-
- subroutine Pump1_Step
- Call Pump1_MainSolver
- end subroutine Pump1_Step
-
- subroutine Pump1_Output
- implicit none
- end subroutine Pump1_Output
-
- subroutine Pump1MainBody
- use ifport
- use ifmt
- !use Pump1_MainSolver
- use CWarningsVariables
- !use equipments_PowerLimit
- implicit none
-
- integer,dimension(8) :: MP_START_TIME, MP_END_TIME
- INTEGER :: MP_SolDuration
-
-
- loop1 : do
-
- Call DATE_AND_TIME(values=MP_START_TIME)
-
- Call Pump1_MainSolver
-
- Call DATE_AND_TIME(values=MP_END_TIME)
- MP_SolDuration = 100-(MP_END_TIME(5)*3600000+MP_END_TIME(6)*60000+MP_END_TIME(7)*1000+MP_END_TIME(8)-MP_START_TIME(5)*3600000-MP_START_TIME(6)*60000-MP_START_TIME(7)*1000-MP_START_TIME(8))
- if(MP_SolDuration > 0.0) then
- Call sleepqq(MP_SolDuration)
- end if
-
- if (IsStopped == .true.) then
- exit loop1
- end if
-
- end do loop1
-
- end subroutine Pump1MainBody
-
-
-
-
-
- ! ****************************************
- ! ***** subroutine Pump2MainBody *****
- ! ****************************
- subroutine Pump2_Setup()
- use CSimulationVariables
- implicit none
- call OnSimulationInitialization%Add(Pump2_Init)
- call OnSimulationStop%Add(Pump2_Init)
- call OnPump2Step%Add(Pump2_Step)
- call OnPump2Output%Add(Pump2_Output)
- call OnPump2Main%Add(Pump2MainBody)
- end subroutine
-
- subroutine Pump2_Init
- implicit none
- end subroutine Pump2_Init
-
- subroutine Pump2_Step
- call Pump2_MainSolver
- end subroutine Pump2_Step
-
- subroutine Pump2_Output
- implicit none
- end subroutine Pump2_Output
-
- subroutine Pump2MainBody
- use ifport
- use ifmt
- use CWarningsVariables
- implicit none
-
- integer,dimension(8) :: MP_START_TIME, MP_END_TIME
- INTEGER :: MP_SolDuration
-
- Call Pump_StartUp
-
- loop1 : do
-
- Call DATE_AND_TIME(values=MP_START_TIME)
-
- Call Pump2_MainSolver
-
- Call DATE_AND_TIME(values=MP_END_TIME)
- MP_SolDuration = 100-(MP_END_TIME(5)*3600000+MP_END_TIME(6)*60000+MP_END_TIME(7)*1000+MP_END_TIME(8)-MP_START_TIME(5)*3600000-MP_START_TIME(6)*60000-MP_START_TIME(7)*1000-MP_START_TIME(8))
- if(MP_SolDuration > 0.0) then
- Call sleepqq(MP_SolDuration)
- end if
-
- if (IsStopped == .true.) then
- exit loop1
- end if
-
- end do loop1
-
-
- end subroutine Pump2MainBody
-
-
-
-
- ! ****************************************
- ! ***** subroutine Pump3MainBody *****
- ! ****************************
- subroutine Pump3_Setup()
- use CSimulationVariables
- implicit none
- call OnSimulationInitialization%Add(Pump3_Init)
- call OnSimulationStop%Add(Pump3_Init)
- call OnPump3Step%Add(Pump3_Step)
- call OnPump3Output%Add(Pump3_Output)
- call OnPump3Main%Add(Pump3MainBody)
- end subroutine
-
- subroutine Pump3_Init
- implicit none
- end subroutine Pump3_Init
-
- subroutine Pump3_Step
- implicit none
- end subroutine Pump3_Step
-
- subroutine Pump3_Output
- implicit none
- end subroutine Pump3_Output
-
- subroutine Pump3MainBody
- use ifport
- use ifmt
- implicit none
-
-
- integer,dimension(8) :: MP_START_TIME, MP_END_TIME
- INTEGER :: MP_SolDuration
-
- !Call Pump_StartUp
- !loop1 : do
- !
- ! Call sleepqq(10)
- !
- ! !!! Pump3 Malfunction ----> Power Failure
- ! !!if (PUMP(1)%PowerFailMalf==1) then
- ! !! !MP1BLWR=0
- ! !! Call Pump3_OffMode_Solver
- ! !! Call ClosePump1()
- ! !!end if
- !
- ! !if( (MP1CPSwitch==1) .and. (MP1Throttle==0.) .and. (PUMP(3)%PowerFailMalf==0) ) then
- !!
- !! loop2: do
- !!
- !! Call DATE_AND_TIME(values=MP_START_TIME)
- !!
- !!!! ! Pump3 Malfunction ----> Power Failure
- !!!! if (PUMP(1)%PowerFailMalf==1) then
- !!!! !MP1BLWR=0
- !!!! Pump3_OffMode_Solver
- !!!! Call ClosePump1()
- !!!! exit loop2
- !!!! end if
- !!
- !! PUMP(3)%N_new = MP1Throttle
- !! if (((PUMP(3)%N_new-PUMP(3)%N_old)/PUMP(3)%time_step)>193.) then
- !! PUMP(3)%N_ref =(193.*PUMP(3)%time_step)+PUMP(3)%N_old
- !! else if (((PUMP(3)%N_old-PUMP(3)%N_new)/PUMP(3)%time_step)>193.) then
- !! PUMP(3)%N_ref = (-193.*PUMP(3)%time_step)+PUMP(3)%N_old
- !! else
- !! PUMP(3)%N_ref = PUMP(3)%N_new
- !! end if
- !!
- !! Call Pump3_OnMode_Solver
- !!
- !! IF (PUMP(3)%Flow_Rate>0.) Then
- !! Call OpenCementPump()
- !! Else
- !! Call CloseCementPump()
- !! End if
- !!
- !! PUMP(3)%N_old = PUMP(3)%N_ref
- !!
- !! Call DATE_AND_TIME(values=MP_END_TIME)
- !! MP_SolDuration = 100-(MP_END_TIME(6)*60000+MP_END_TIME(7)*1000+MP_END_TIME(8)-MP_START_TIME(6)*60000-MP_START_TIME(7)*1000-MP_START_TIME(8))
- !! !print*, 'MPtime=', MP_SolDuration
- !! if(MP_SolDuration > 0.0) then
- !! Call sleepqq(MP_SolDuration)
- !! end if
- !!
- !! if ((MP1CPSwitch==0) .or. (IsStopped == .true.)) then
- !! Call Pump3_OffMode_Solver
- !! Call CloseCementPump()
- !! exit loop2
- !! end if
- !! end do loop2
- !
- ! else
- !
- ! !Call Pump3_OffMode_Solver
- ! !Call CloseCementPump()
- !
- ! end if
- !
- ! if (IsStopped == .true.) then
- ! exit loop1
- ! end if
- !
- !end do loop1
-
-
- end subroutine Pump3MainBody
-
- end module PumpsMain
|