  1. # 1 "/home/admin/SimulationCore2/Equipments/Pumps/Pump_OffMode_Solver.f90"
  2. subroutine Pump_OffMode_Solver(Pump_No)
  3. use SimulationVariables
  4. IMPLICIT NONE
  5. INTEGER :: Pump_No
  6. data%State%Pump(Pump_No)%N_new = 0.d0
  7. !========================== Pump Rate limit ==========================
  8. if (((data%State%Pump(Pump_No)%N_new-data%State%Pump(Pump_No)%N_old)/data%State%Pump(Pump_No)%time_step)>data%State%Pump(Pump_No)%RateChange) then
  9. data%State%Pump(Pump_No)%Speed =(data%State%Pump(Pump_No)%RateChange*data%State%Pump(Pump_No)%time_step)+data%State%Pump(Pump_No)%N_old
  10. else if (((data%State%Pump(Pump_No)%N_old-data%State%Pump(Pump_No)%N_new)/data%State%Pump(Pump_No)%time_step)>data%State%Pump(Pump_No)%RateChange) then
  11. data%State%Pump(Pump_No)%Speed = (-data%State%Pump(Pump_No)%RateChange*data%State%Pump(Pump_No)%time_step)+data%State%Pump(Pump_No)%N_old
  12. else
  13. data%State%Pump(Pump_No)%Speed = data%State%Pump(Pump_No)%N_new
  14. end if
  15. !=======================================================================
  16. data%State%Pump(Pump_No)%Flow_Rate = data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio) ![gpm]
  17. data%State%Pump(Pump_No)%HorsePower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%StandPipe_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
  18. !data%State%Pump(Pump_No)%Max_Horsepower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%Max_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
  19. data%State%Pump(Pump_No)%Max_Horsepower = (data%State%Pump(Pump_No)%Flow_Rate*data%State%Pump(Pump_No)%Max_Pressure)/(1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency)
  20. if ( data%State%Pump(Pump_No)%StandPipe_Pressure>data%State%Pump(Pump_No)%Max_Pressure ) then ! in shart check shavad
  21. !if ( (data%State%Pump(Pump_No)%StandPipe_Pressure*data%State%Pump(Pump_No)%Flow_Rate)>(1714.d0*data%State%Pump(Pump_No)%Max_Horsepower*data%State%Pump(Pump_No)%Mech_Efficiency) ) then
  22. data%State%Pump(Pump_No)%Flow_Rate = (1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency*data%State%Pump(Pump_No)%Max_Horsepower)/data%State%Pump(Pump_No)%StandPipe_Pressure ![gpm]
  23. data%State%Pump(Pump_No)%Speed = ( data%State%Pump(Pump_No)%Flow_Rate/(data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0) )*data%State%Pump(Pump_No)%Trans_Ratio ![rpm]
  24. end if
  25. data%State%Pump(Pump_No)%SoundSPM = INT(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio)
  26. If (data%State%Pump(Pump_No)%Flow_Rate>0.d0) Then
  27. data%State%Pump(Pump_No)%Open_Close = 1
  28. Else
  29. data%State%Pump(Pump_No)%Open_Close = 0
  30. End if
  31. end subroutine Pump_OffMode_Solver