  1. SUBROUTINE ANNULAR_SUB1
  2. USE VARIABLES
  3. USE CBopControlPanelVariables
  4. USE PressureDisplayVARIABLES
  5. USE CEquipmentsConstants
  6. USE CBopStackVariables
  7. implicit none
  8. !write(*,*) 'checkpoint 1'
  9. !=====================================================================
  10. ! ANNULAR PREVENTER- BOP CAMERON Type U 5000
  11. ! START CONDITIONS FOR ANNULAR PREVENTER
  12. !=====================================================================
  13. RAM(1)%SuccessionCounter = RAM(1)%SuccessionCounter + 1
  14. if (BopControlPanel%AnnularValve == 1.0 .and. Annular%AnnularFailureMalf==0 .and. BopStackAcc%RigAirMalf==0 .and. BopControlPanel%AirMasterValve==1) then
  15. if (BopStackInput%AnnularCloseLedMine == LedOn) then
  16. RETURN
  17. end if
  18. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  19. RAM(1)%SuccessionCounter = 0 ! also in starup
  20. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  21. !return
  22. else
  23. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  24. endif
  25. if ( RAM(1)%SuccessionCounter >= int(2.5/RamLine%DeltaT_BOP) ) then
  26. !return
  27. RAM(1)%First_CloseTimecheck= 1
  28. BopControlPanel%AnnularOpenLED = LedOff
  29. BopStackInput%AnnularOpenLedMine = LedOff
  30. BopControlPanel%AnnularCloseLED = LedOn !LedBlinking
  31. RAM(1)%FourwayValve = 1
  32. endif
  33. endif
  34. if (RAM(1)%FourwayValve == 1 .and. RamLine%P_ACC>BopStackAcc%acc_MinPressure .and. Annular%Pannular_reg>AnnularComputational%AnnularMovingPressure) then ! 1: Open , 0: Close
  35. RAM(1)%FourwayValve = 0
  36. Annular%Annular_closed=0
  37. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  38. RAM(1)%vdis_tot=0
  39. RAM(1)%vdis_bottles=0.
  40. RAM(1)%fvr_air=0.
  41. RAM(1)%vdis_elecp=0.
  42. Pumps%Qiter=7
  43. RAM(1)%Qzero=70
  44. RAM(1)%Q=RAM(1)%Qzero
  45. RAM(1)%flow=70
  46. Annular%tolAnnular=0.0018
  47. if (Annular%finished_Annular==1) then
  48. Annular%AnnularLeverOld=-1.0
  49. else
  50. Annular%AnnularLeverOld=BopControlPanel%AnnularValve
  51. endif
  52. Annular%finished_Annular=0
  53. Annular%AnnularIsClosing = .true.
  54. Annular%AnnularIsOpening = .false.
  55. RAM(2)%bop_type = 3
  56. !AbopAnnular=963.1 !(in^2)
  57. Annular%AbopAnnular=(BopStackSpecification%AnnularPreventerClose*231.)/((Annular%IDAnnularBase-Annular%ODDrillpipe_inAnnularBase)/2.) ! 231 in^3 = 1 gal
  58. Annular%NeededVolumeAnnular=Annular%AbopAnnular*(Annular%IDAnnularBase-max(Annular%ODDrillpipe_inAnnular,Annular%ODDrillpipe_inAnnularBase))/(2.*231) !=17.98 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnularBase=5
  59. !WRITE(*,*) 'a)NeededVolumeAnnular=' , NeededVolumeAnnular
  60. !write(*,*) 'close 1'
  61. endif
  62. if (BopControlPanel%AnnularValve == -1.0 .and. Annular%AnnularFailureMalf==0 .and. BopStackAcc%RigAirMalf==0 .and. BopControlPanel%AirMasterValve==1 ) then
  63. if (BopStackInput%AnnularOpenLedMine == LedOn) then
  64. RETURN
  65. end if
  66. !CasingPressure : PressureGauges(2) *****temp conditionssssss
  67. !note: (AnnularSealingPressure) is only for opening while well is pressurised
  68. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  69. RAM(1)%SuccessionCounter = 0 ! also in starup
  70. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  71. !return
  72. else
  73. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  74. endif
  75. if ( RAM(1)%SuccessionCounter >= int(2.5/RamLine%DeltaT_BOP) ) then
  76. !return
  77. RAM(1)%First_OpenTimecheck= 1
  78. BopControlPanel%AnnularCloseLED = LedOff !new
  79. BopStackInput%AnnularCloseLedMine = LedOff !new
  80. BopControlPanel%AnnularOpenLED = LedOn !LedBlinking
  81. RAM(1)%FourwayValve = 1
  82. endif
  83. endif
  84. if (RAM(1)%FourwayValve == 1 .and. Annular%Pannular_reg>AnnularComputational%AnnularMovingPressure .and. RamLine%P_ACC>BopStackAcc%acc_MinPressure &
  85. .and. (Annular%Annular_closed==0 .or. (Annular%Annular_closed==1 .and.PressureGauges(2) <=100.0) .or. (Annular%Annular_closed==1 .and.PressureGauges(2)>100.0 .and. Annular%Pannular_reg>=AnnularComputational%AnnularSealingPressure))) then ! 1: Open , 0: Close
  86. !write(*,*) 'open 2'
  87. RAM(1)%FourwayValve = 0
  88. Annular%Annular_closed=0
  89. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  90. RAM(1)%vdis_tot=0
  91. RAM(1)%vdis_bottles=0.
  92. RAM(1)%fvr_air=0.
  93. RAM(1)%vdis_elecp=0.
  94. Pumps%Qiter=7
  95. RAM(1)%Qzero=70
  96. RAM(1)%Q=RAM(1)%Qzero
  97. RAM(1)%flow=70
  98. Annular%tolAnnular=0.0018
  99. if (Annular%finished_Annular==1) then
  100. Annular%AnnularLeverOld=1.0
  101. else
  102. Annular%AnnularLeverOld=BopControlPanel%AnnularValve
  103. endif
  104. Annular%finished_Annular=0
  105. Annular%AnnularIsOpening = .true.
  106. Annular%AnnularIsClosing = .false.
  107. !if (AnnularOpenLed == LedOn) then
  108. ! RETURN
  109. !end if
  110. RAM(1)%bop_type = 3
  111. !AbopAnnular=758.48 !(in^2)
  112. Annular%AbopAnnular=(BopStackSpecification%AnnularPreventerOpen*231)/((Annular%IDAnnularBase-max(Annular%ODDrillpipe_inAnnular,Annular%ODDrillpipe_inAnnularBase))/2.)
  113. Annular%NeededVolumeAnnular=Annular%AbopAnnular*(Annular%IDAnnularBase-Annular%ODDrillpipe_inAnnular)/(2.*231) !=14.16 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnular=5
  114. !write(*,*) 'open 1'
  115. endif
  116. !=====================================================================
  117. if (Annular%AnnularIsOpening .or. Annular%AnnularIsClosing .or. RAM(1)%Bottles_Charged_MalfActive) then
  118. CALL ANNULAR_SUB2
  119. end if
  120. END SUBROUTINE ANNULAR_SUB1
  121. SUBROUTINE ANNULAR_SUB2
  122. USE VARIABLES
  123. USE PressureDisplayVARIABLES
  124. USE CBopControlPanelVariables
  125. USE CEquipmentsConstants
  126. USE CBopStackVariables
  127. ! use CSimulationVariables
  128. implicit none
  129. Annular%FirstSet= 0
  130. AnnularComputational%RamsFirstSet= 0
  131. ! loop5: do while (finished_Annular==0)
  132. !write(*,*) 'checkpoint 2'
  133. RAM(1)%SuccessionCounter = RAM(1)%SuccessionCounter + 1
  134. ! CALL CPU_TIME(Annular_StartTime)
  135. if (BopControlPanel%AnnularValve == 1.0 .and. Annular%AnnularLeverOld == -1.0 .and. Annular%AnnularFailureMalf==0 .and. BopStackAcc%RigAirMalf==0 .and. BopControlPanel%AirMasterValve==1) then
  136. if ( RAM(1)%First_CloseTimecheck == 0 ) then
  137. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  138. RAM(1)%SuccessionCounter = 0 ! also in starup
  139. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  140. !return
  141. else
  142. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  143. endif
  144. if ( RAM(1)%SuccessionCounter >= int(2.5/RamLine%DeltaT_BOP) ) then
  145. !return
  146. BopControlPanel%AnnularOpenLED = LedOff
  147. BopStackInput%AnnularOpenLedMine = LedOff
  148. BopControlPanel%AnnularCloseLED = LedOn !LedBlinking
  149. RAM(1)%FourwayValve = 1
  150. endif
  151. endif
  152. !write(*,*) 'chekkk 1'
  153. endif
  154. if (RAM(1)%FourwayValve == 1 .and. Annular%Pannular_reg>AnnularComputational%AnnularMovingPressure .and. RamLine%P_ACC>BopStackAcc%acc_MinPressure) then
  155. !write(*,*) 'close 4'
  156. RAM(1)%FourwayValve = 0
  157. Annular%Annular_closed=0
  158. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  159. AnnularComputational%p_annular=AnnularComputational%pa_annular
  160. Annular%AnnularLeverOld = BopControlPanel%AnnularValve
  161. CALL OpenAnnular
  162. Annular%Annular_Situation_forTD= 0 ! open - for TD code
  163. RAM(1)%bop_type = 3
  164. !AbopAnnular=963.1 !(in^2)
  165. Annular%AbopAnnular=(BopStackSpecification%AnnularPreventerClose*231)/((Annular%IDAnnularBase-Annular%ODDrillpipe_inAnnularBase)/2.)
  166. !write(*,*) 'NeededVolumeShearRams1=',NeededVolumeShearRams
  167. Annular%NeededVolumeAnnular=Annular%AbopAnnular*(Annular%IDAnnular-max(Annular%ODDrillpipe_inAnnular,Annular%ODDrillpipe_inAnnularBase))/(2*231.)
  168. ! write(*,*) 'NeededVolumeAnnular=',NeededVolumeAnnular
  169. RAM(1)%vdis_bottles=0.
  170. RAM(1)%fvr_air=0.
  171. RAM(1)%vdis_elecp=0.
  172. Annular%AnnularIsClosing = .true.
  173. Annular%AnnularIsOpening = .false.
  174. !write(*,*) 'close 2'
  175. endif
  176. if (BopControlPanel%AnnularValve == -1.0 .and. Annular%AnnularLeverOld == 1.0 .and. RamLine%P_ACC>BopStackAcc%acc_MinPressure .and. Annular%AnnularFailureMalf==0 .and. BopStackAcc%RigAirMalf==0 .and. BopControlPanel%AirMasterValve==1 ) then
  177. !CasingPressure : PressureGauges(2) *****temp conditionssssss
  178. !note: (AnnularSealingPressure) is only for opening while well is pressurised
  179. if ( RAM(1)%First_OpenTimecheck == 0 ) then
  180. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  181. RAM(1)%SuccessionCounter = 0 ! also in starup
  182. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  183. !return
  184. else
  185. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  186. endif
  187. if ( RAM(1)%SuccessionCounter >= int(2.5/RamLine%DeltaT_BOP) ) then
  188. !return
  189. BopControlPanel%AnnularCloseLED = LedOff
  190. BopStackInput%AnnularCloseLedMine= LedOff
  191. BopControlPanel%AnnularOpenLED = LedOn !LedBlinking
  192. RAM(1)%FourwayValve = 1
  193. endif
  194. endif
  195. !write(*,*) 'chekkk 2'
  196. endif
  197. if (RAM(1)%FourwayValve == 1 .and. Annular%Pannular_reg>AnnularComputational%AnnularMovingPressure &
  198. .and. (Annular%Annular_closed==0 .or. (Annular%Annular_closed==1 .and.PressureGauges(2) <=100.0) .or. (Annular%Annular_closed==1 .and.PressureGauges(2)>100.0 .and. Annular%Pannular_reg>=AnnularComputational%AnnularSealingPressure))) then
  199. !write(*,*) 'open 4'
  200. RAM(1)%FourwayValve = 0
  201. Annular%Annular_closed=0
  202. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  203. AnnularComputational%p_annular=AnnularComputational%pa_annular
  204. Annular%AnnularLeverOld = BopControlPanel%AnnularValve
  205. CALL OpenAnnular
  206. Annular%Annular_Situation_forTD= 0 ! open - for TD code
  207. RAM(1)%bop_type = 3
  208. !AbopAnnular=758.48 !(in^2)
  209. Annular%AbopAnnular=(BopStackSpecification%AnnularPreventerOpen*231)/((Annular%IDAnnularBase-Annular%ODDrillpipe_inAnnularBase)/2.)
  210. Annular%NeededVolumeAnnular=Annular%AbopAnnular*(Annular%IDAnnularBase-Annular%IDAnnular)/(2*231.)
  211. RAM(1)%vdis_bottles=0.
  212. RAM(1)%fvr_air=0.
  213. RAM(1)%vdis_elecp=0.
  214. Annular%AnnularIsOpening = .true.
  215. Annular%AnnularIsClosing = .false.
  216. !write(*,*) 'open 2'
  217. endif
  218. RAM(1)%First_CloseTimecheck = 0
  219. RAM(1)%First_OpenTimecheck = 0
  220. RAM(1)%time=RAM(1)%time+RamLine%DeltaT_BOP !overal time (s)
  221. !===================================================
  222. ! BOP
  223. !===================================================
  224. if (Annular%Annular_closed==0) then !bop closing
  225. !write(*,*) 'AnnularIsClosing,AnnularIsOpening' , AnnularIsClosing,AnnularIsOpening
  226. call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
  227. endif !bop is closing
  228. !================================================================
  229. if (Annular%Annular_closed==1) then
  230. RAM(1)%Q=0
  231. !p_bop=pram_reg
  232. AnnularComputational%p_annular=AnnularComputational%pa_annular
  233. endif
  234. RAM(1)%timecounter_ram=RAM(1)%timecounter_ram+1
  235. ! MiddleRamsStatus = IDshearBop
  236. ! UpperRamsStatus = IDPipeRam1
  237. ! LowerRamsStatus = IDPipeRam2
  238. ! AnnularStatus = IDAnnular
  239. ! AccumulatorPressureGauge = p_acc
  240. ! ManifoldPressureGauge= pram_reg
  241. ! AnnularPressureGauge=Pannular_reg
  242. !
  243. !
  244. !
  245. ! WRITE(60,60) RAM(1)%time,RAM(1)%Q,RAM(1)%vdis_tot,p_acc, &
  246. ! pram_reg,Pannular_reg,RAM(1)%p_bop,IDshearBop, &
  247. ! IDPipeRam1,IDPipeRam2,IDAnnular
  248. !60 FORMAT(11(f18.5))
  249. ! call sleepqq(100)
  250. !CALL CPU_TIME(Annular_EndTime)
  251. !
  252. !
  253. !PUMP(1)%INT_CPU_TIME=IDINT((Annular_EndTime-Annular_StartTime)*1000.)
  254. !PUMP(1)%Dt_ref=IDINT(DeltaT_BOP*1000.)
  255. !
  256. !call sleepqq(PUMP(1)%Dt_ref-PUMP(1)%INT_CPU_TIME)
  257. if (Annular%Annular_closed==1) then
  258. ! if ((MiddleRamsValve==1. .and. MiddleRamsFailureMalf==0) .or. (MiddleRamsValve==-1.0 .and. MiddleRamsFailureMalf==0) .or. (LowerRamsValve==1. .and. LowerRamsFailureMalf==0) .or. (LowerRamsValve==-1.0 .and. LowerRamsFailureMalf==0) .or. (UpperRamsValve==1. .and. UpperRamsFailureMalf==0) .or. (UpperRamsValve==-1.0 .and. UpperRamsFailureMalf==0) .or. ChokeLineValve==1. .or. ChokeLineValve==-1.0 .or. KillLineValve==1. .or. KillLineValve==-1.0) then
  259. Annular%finished_Annular=1
  260. ! endif
  261. endif
  262. ! if (IsStopped == .true.) return
  263. ! end do loop5 !while finished_Annular==0
  264. if ( Annular%finished_Annular==1 .and. RAM(1)%Bottles_Charged_MalfActive==.true.) then
  265. call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
  266. ! call sleepqq(100)
  267. endif
  268. END SUBROUTINE ANNULAR_SUB2