- # 1 "/home/admin/SimulationCore2/Equipments/Pumps/Pump1_MainSolver.f90"
- subroutine Pump1_MainSolver
-
- use SimulationVariables
-
- Implicit none
-
-
-
-
- if (data%State%Pump(1)%Throttle<=0.d0) then
- data%State%Pump(1)%K_throttle = 1
- end if
-
-
- if((any(data%State%Pump(1)%AssignmentSwitchh==(/1,2,3,4,9,10/))) .and. (data%State%Pump(1)%Switch==-1) .and. (data%State%Pump(1)%K_throttle==1) .and. (data%State%Pump(1)%PowerFailMalf==0) .and. (data%State%Pump(1)%Failure==0)) then
-
- data%State%Pump(1)%SoundBlower = .true.
- data%State%Pump(1)%BLWR = 1
-
- !========================== Pump 1 Rate limit ==========================
- if (((data%State%Pump(1)%N_new-data%State%Pump(1)%N_old)/data%State%Pump(1)%time_step)>data%State%Pump(1)%RateChange) then
- data%State%Pump(1)%Speed =(data%State%Pump(1)%RateChange*data%State%Pump(1)%time_step)+data%State%Pump(1)%N_old ![RPM]
- else if (((data%State%Pump(1)%N_old-data%State%Pump(1)%N_new)/data%State%Pump(1)%time_step)>data%State%Pump(1)%RateChange) then
- data%State%Pump(1)%Speed = (-data%State%Pump(1)%RateChange*data%State%Pump(1)%time_step)+data%State%Pump(1)%N_old
- else
- data%State%Pump(1)%Speed = data%State%Pump(1)%N_new
- end if
- !=======================================================================
-
- Call Pump_OnMode_Solver(1)
-
- else
-
- if ((any(data%State%Pump(1)%AssignmentSwitchh==(/1,2,3,4,9,10/))) .and. (data%State%Pump(1)%Switch==-1)) then
- data%State%Pump(1)%SoundBlower = .true.
- else
- data%State%Pump(1)%SoundBlower = .false.
- end if
-
- if ((any(data%State%Pump(1)%AssignmentSwitchh==(/1,2,3,4,9,10/))) .and. (data%State%Pump(1)%Switch==-1) .and. (data%State%Pump(1)%PowerFailMalf==0) .and. (data%State%Pump(1)%Failure==0)) then
- data%State%Pump(1)%BLWR = 1
- else
- data%State%Pump(1)%BLWR = 0
- end if
-
-
- Call Pump_OffMode_Solver(1)
- data%State%Pump(1)%K_throttle = 0
-
- end if
-
-
- data%State%Pump(1)%N_old = data%State%Pump(1)%Speed
-
-
-
- end subroutine Pump1_MainSolver
|