|
- # 1 "/mnt/c/Projects/VSIM/SimulationCore2/Equipments/ChokeControl/AirPump_Choke_Subs.f90"
-
- SUBROUTINE DEALLOCATE_ARRAYS_CHOKE()
-
- USE CHOKEVARIABLES
- use SimulationVariables !@
-
- implicit none
- write(*,*) 'deallocateeeeeeeeeeeee'
- !===========================================================================
- ! AIR PUMP LOSSES INPUT
- !===========================================================================
- !if(allocated(PIPINGS_AIRPUMP)) deallocate(PIPINGS_AIRPUMP)
-
- DEALLOCATE (data%State%AirPumpLine%PIPINGS_AIRPUMP,data%State%AirPumpLine%DIAM_AIR_INCH, &
- data%State%AirPumpLine%Re_air,data%State%AirPumpLine%AREA_AIR,data%State%AirPumpLine%LENGT_AIR,data%State%AirPumpLine%ROUGHNESS_AIRPLINE,data%State%AirPumpLine%REL_ROUGHAIR, &
- data%State%AirPumpLine%fric_air,data%State%AirPumpLine%fricloss_air)
- !================================================================
- DEALLOCATE (data%State%AirPumpLine%MINORS_AIRPUMP,data%State%AirPumpLine%MINORDIAM_AIR_INCH, &
- data%State%AirPumpLine%MINORAREA_AIR,data%State%AirPumpLine%LF_AIR,data%State%AirPumpLine%CV_AIR,data%State%AirPumpLine%NOTE_AIR &
- ,data%State%AirPumpLine%minlosspa_air,data%State%AirPumpLine%minloss_air)
-
- END
-
-
-
-
-
-
- SUBROUTINE LOSS_INPUTS_CHOKE()
- USE CHOKEVARIABLES
- use SimulationVariables !@
- implicit none
- Integer I
-
-
- !===========================================================================
- ! AIR PUMP LOSSES INPUT
- !===========================================================================
- data%State%AirPumpLine%NO_PIPINGS_AIRPLINE=1
-
- ALLOCATE (data%State%AirPumpLine%PIPINGS_AIRPUMP(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE,3))
- ! ID(INCH) L(MM) ROUGHNESS(MM)=e DESCRIPTION
- data%State%AirPumpLine%PIPINGS_AIRPUMP(1,1:3)= (/0.5, 60960., 0.03/) !Avg.acc.distance
-
- !60960= 200 ft
-
-
- ALLOCATE (data%State%AirPumpLine%DIAM_AIR_INCH(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE),data%State%AirPumpLine%Re_air(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE),data%State%AirPumpLine%AREA_AIR(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE), &
- data%State%AirPumpLine%LENGT_AIR(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE),data%State%AirPumpLine%ROUGHNESS_AIRPLINE(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE),data%State%AirPumpLine%REL_ROUGHAIR(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE), &
- data%State%AirPumpLine%fric_air(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE),data%State%AirPumpLine%fricloss_air(data%State%AirPumpLine%NO_PIPINGS_AIRPLINE))
-
-
-
- DO I=1,data%State%AirPumpLine%NO_PIPINGS_AIRPLINE
- data%State%AirPumpLine%DIAM_AIR_INCH(I)=data%State%AirPumpLine%PIPINGS_AIRPUMP(I,1)
- data%State%AirPumpLine%LENGT_AIR(I)=data%State%AirPumpLine%PIPINGS_AIRPUMP(I,2)
- data%State%AirPumpLine%ROUGHNESS_AIRPLINE(I)=data%State%AirPumpLine%PIPINGS_AIRPUMP(I,3)
-
-
- data%State%AirPumpLine%AREA_AIR(I)=PI*(data%State%AirPumpLine%DIAM_AIR_INCH(I)*0.0254)**2/4 !D(in), AREA(m)
- data%State%AirPumpLine%REL_ROUGHAIR(I)=data%State%AirPumpLine%ROUGHNESS_AIRPLINE(I)/(data%State%AirPumpLine%DIAM_AIR_INCH(I)*25.4)
- !DIAM_RAMLINE_MM(I)=DIAM_RAMLINE_MM(I)*.001 ! (m)
- data%State%AirPumpLine%LENGT_AIR(I)=data%State%AirPumpLine%LENGT_AIR(I)*.001 ! (m)
- ENDDO
-
-
- !================================================================
- data%State%AirPumpLine%NO_MINORS_AIRPLINE=6
-
- ALLOCATE (data%State%AirPumpLine%MINORS_AIRPUMP(data%State%AirPumpLine%NO_MINORS_AIRPLINE,4))
-
- ! ID(INCH) LF CV NOTE(BAR) DESCRIPTION
- data%State%AirPumpLine%MINORS_AIRPUMP(1,1:4)= (/2., 10., 0., 0./) !Acc.tee
- data%State%AirPumpLine%MINORS_AIRPUMP(2,1:4)= (/2., 11., 0., 0./) !elbow
- data%State%AirPumpLine%MINORS_AIRPUMP(3,1:4)= (/1., 0., 0., 3.4/) !filter
- data%State%AirPumpLine%MINORS_AIRPUMP(4,1:4)= (/2., 0., 105., 0./) !valve
- data%State%AirPumpLine%MINORS_AIRPUMP(5,1:4)= (/1., 0., 9.2, 0./) !valve
- data%State%AirPumpLine%MINORS_AIRPUMP(6,1:4)= (/2., 6.4, 0., 0./) !unionA
-
-
-
- ALLOCATE (data%State%AirPumpLine%MINORDIAM_AIR_INCH(data%State%AirPumpLine%NO_MINORS_AIRPLINE),data%State%AirPumpLine%MINORAREA_AIR(data%State%AirPumpLine%NO_MINORS_AIRPLINE), &
- data%State%AirPumpLine%LF_AIR(data%State%AirPumpLine%NO_MINORS_AIRPLINE),data%State%AirPumpLine%CV_AIR(data%State%AirPumpLine%NO_MINORS_AIRPLINE),data%State%AirPumpLine%NOTE_AIR(data%State%AirPumpLine%NO_MINORS_AIRPLINE) &
- ,data%State%AirPumpLine%minlosspa_air(data%State%AirPumpLine%NO_MINORS_AIRPLINE),data%State%AirPumpLine%minloss_air(data%State%AirPumpLine%NO_MINORS_AIRPLINE))
-
-
-
- DO I=1,data%State%AirPumpLine%NO_MINORS_AIRPLINE
- data%State%AirPumpLine%MINORDIAM_AIR_INCH(I)=data%State%AirPumpLine%MINORS_AIRPUMP(I,1)
- data%State%AirPumpLine%LF_AIR(I)=data%State%AirPumpLine%MINORS_AIRPUMP(I,2)
- data%State%AirPumpLine%CV_AIR(I)=data%State%AirPumpLine%MINORS_AIRPUMP(I,3)
- data%State%AirPumpLine%NOTE_AIR(I)=data%State%AirPumpLine%MINORS_AIRPUMP(I,4)
-
-
- data%State%AirPumpLine%MINORAREA_AIR(I)=PI*(data%State%AirPumpLine%MINORDIAM_AIR_INCH(I)*0.0254)**2/4. !D(in), AREA(m)
- ENDDO
-
-
- END
-
-
-
-
-
- ! SUBROUTINE PIPE_RAMS_CHOKE(CHNUMBER)
- ! USE CHOKEVARIABLES
- ! use ConfigurationVariables !@
- ! Use CSimulationVariables
- ! implicit none
- ! INTEGER CHNUMBER
- ! Integer I
-
- ! loop3: do while (ABS(data%Equipments%ChokeControlPanel%ChokeControlLever)==1.0 .AND. data%Equipments%ChokeControlPanel%ChokePanelRigAirSwitch == 1 .AND. data%State%CHOOKE(CHNUMBER)%FailMalf==0 .AND. data%State%AirDrivenPump%ChokeAirFail==0)
- ! if (data%Equipments%ChokeControlPanel%ChokeControlLever == 1.0) then
- ! data%State%CHOOKE(CHNUMBER)%ChokeIsClosing = .true.
- ! data%State%CHOOKE(CHNUMBER)%ChokeIsOpening = .false.
- ! endif
- ! if (data%Equipments%ChokeControlPanel%ChokeControlLever == -1.0) then
- ! data%State%CHOOKE(CHNUMBER)%ChokeIsOpening = .true.
- ! data%State%CHOOKE(CHNUMBER)%ChokeIsClosing = .false.
- ! endif
- ! data%State%AirPumpLine%TIME=data%State%AirPumpLine%TIME+data%State%AirPumpLine%DeltaT_Choke !overal time (s)
- ! call airpump_code_CHOKE(CHNUMBER)
- ! call sleepqq(100)
- ! if (IsStopped == .true.) return
- ! end do loop3 !while finished_Choke==0
- ! end
-
-
-
-
-
-
- SUBROUTINE airpump_code_CHOKE(CHNUMBER)
- USE CHOKEVARIABLES
- use SimulationVariables !@
- use CChokeManifold
- use SimulationVariables
- use CSounds
- USE CChokeProblemsVariables
- implicit none
- Integer I
-
- INTEGER CHNUMBER
-
- data%State%AirDrivenPump%QAIR_PUMP=data%State%AirPumpLine%QITER+.1 !(gpm) maximum flow for the start
- data%State%AirPumpLine%diffp_air=-10
- data%State%AirPumpLine%losses_air=10
-
- !===================================================================
- ! AIR OPERATED PUMP
- ! MODEL 10-6000W030 RATIO 55:1
- !=================for air consumption at 100 psig===================
- do while (data%State%AirPumpLine%diffp_air<0)
- data%State%AirDrivenPump%QAIR_PUMP=data%State%AirDrivenPump%QAIR_PUMP-.1
- ! Qup=data%State%AirDrivenPump%QAIR_PUMP;
- !cc1 = 1354; cc2 = -2066; cc3 = -2109; cc4 = -513.6; cc5 = 5935 FOR OUTPUT IN GPM
- data%State%AirPumpLine%P_AIRP=data%State%AirDrivenPump%cc1*(data%State%AirDrivenPump%QAIR_PUMP**4) + data%State%AirDrivenPump%cc2*(data%State%AirDrivenPump%QAIR_PUMP**3) + data%State%AirDrivenPump%cc3*(data%State%AirDrivenPump%QAIR_PUMP**2) + data%State%AirDrivenPump%cc4*data%State%AirDrivenPump%QAIR_PUMP + data%State%AirDrivenPump%cc5 !(psig)
- ! kinetic_air=sg*wdens*(QAIR_PUMP*6.30902e-5/((1/4.)*pi*(2*0.254e-1)**2))**2/(2*6895) !(psi)
- data%State%AirPumpLine%diffp_air= data%State%AirPumpLine%P_AIRP - data%State%AirPumpLine%Pdownstrem
- end do !returns Qup
-
- do while (abs((data%State%AirPumpLine%diffp_air-data%State%AirPumpLine%losses_air)/data%State%AirPumpLine%diffp_air)>data%State%AirPumpLine%TOL_AIR) !finding correct QAIR_pump for 1 timecounter_ram
- if (data%State%AirPumpLine%diffp_air-data%State%AirPumpLine%losses_air>0) then
- data%State%AirDrivenPump%QAIR_PUMP=data%State%AirDrivenPump%QAIR_PUMP+.005
- else
- data%State%AirDrivenPump%QAIR_PUMP=data%State%AirDrivenPump%QAIR_PUMP-.005
- endif
- !===================================================================
- ! AIR OPERATED PUMP
- ! MODEL 10-6000W030 RATIO 55:1
- !=================for air consumption at 100 psig===================
- data%State%AirPumpLine%P_AIRP=data%State%AirDrivenPump%cc1*(data%State%AirDrivenPump%QAIR_PUMP**4) + data%State%AirDrivenPump%cc2*(data%State%AirDrivenPump%QAIR_PUMP**3) + data%State%AirDrivenPump%cc3*(data%State%AirDrivenPump%QAIR_PUMP**2) + data%State%AirDrivenPump%cc4*data%State%AirDrivenPump%QAIR_PUMP + data%State%AirDrivenPump%cc5 !(psig)
- !kinetic_air=sg*wdens*(QAIR_PUMP*6.30902e-005/((1/4.)*pi*(2*0.254e-1)**2))**2/(2*6895) !(psi)
- data%State%AirPumpLine%diffp_air= data%State%AirPumpLine%P_AIRP - data%State%AirPumpLine%Pdownstrem
- !===========================LOSSES====================================
- do i=1,data%State%AirPumpLine%NO_PIPINGS_AIRPLINE
- data%State%AirPumpLine%Re_air(i)=data%State%AirDrivenPump%QAIR_PUMP*6.30902e-005*data%State%AirPumpLine%DIAM_AIR_INCH(I)*0.0254/(data%State%AirPumpLine%AREA_AIR(i)*nu)
- enddo
- do i=1,data%State%AirPumpLine%NO_PIPINGS_AIRPLINE
- if (data%State%AirPumpLine%Re_air(i)<Re_cr) then
- data%State%AirPumpLine%fric_air(i)=64/data%State%AirPumpLine%Re_air(i)
- else
- data%State%AirPumpLine%fric_air(i)=1/(-1.8*log10((data%State%AirPumpLine%REL_ROUGHAIR(i)/3.7)**1.11+6.9/data%State%AirPumpLine%Re_air(i)))**2
- endif
- data%State%AirPumpLine%fricloss_air(i)=((data%State%AirPumpLine%fric_air(i)*(wdens*sg*data%State%AirPumpLine%LENGT_AIR(i)*(data%State%AirDrivenPump%QAIR_PUMP*6.30902e-005/data%State%AirPumpLine%AREA_AIR(i))**2))/(2*data%State%AirPumpLine%DIAM_AIR_INCH(I)*0.0254))/6895
- enddo
-
- data%State%AirPumpLine%pipe_loss1air=sum(data%State%AirPumpLine%fricloss_air) !loss before regulator(psi)
-
- do i=1,data%State%AirPumpLine%NO_MINORS_AIRPLINE
- if (data%State%AirPumpLine%LF_AIR(i)/=0) then
- data%State%AirPumpLine%minlosspa_air(i)=data%State%AirPumpLine%LF_AIR(i)*wdens*sg*(data%State%AirDrivenPump%QAIR_PUMP*6.30902e-005/data%State%AirPumpLine%MINORAREA_AIR(i))**2/2 !(Pa)
- data%State%AirPumpLine%minloss_air(i)=data%State%AirPumpLine%minlosspa_air(i)/6895 !(psi)
- elseif (data%State%AirPumpLine%CV_AIR(i)/=0) then
- data%State%AirPumpLine%minlosspa_air(i)=1000*sg*((11.7*data%State%AirDrivenPump%QAIR_PUMP*6.30902e-005*3600)/(data%State%AirPumpLine%CV_AIR(i)))**2 !(pa)
- data%State%AirPumpLine%minloss_air(i)=data%State%AirPumpLine%minlosspa_air(i)/6895 !(psi)
- else
- data%State%AirPumpLine%minlosspa_air(i)=data%State%AirPumpLine%NOTE_AIR(i)*1e5 !(pa)
- data%State%AirPumpLine%minloss_air(i)=data%State%AirPumpLine%minlosspa_air(i)/6895 !(psi)
- endif
- enddo
-
- data%State%AirPumpLine%minor_loss1air=sum(data%State%AirPumpLine%minloss_air) !loss before regulator(psi)
- data%State%AirPumpLine%static_loss1air=0
- data%State%AirPumpLine%losses_air=data%State%AirPumpLine%pipe_loss1air+data%State%AirPumpLine%minor_loss1air+data%State%AirPumpLine%static_loss1air !(psi)
- !=========================================================================
- end do !returns correct QAIR_PUMP for 1 counter
-
- data%State%AirPumpLine%QITER=data%State%AirDrivenPump%QAIR_PUMP
- data%State%AirDrivenPump%QAIR_PUMP=data%State%AirDrivenPump%QAIR_PUMP*(data%Equipments%ChokeControlPanel%ChokeRateControlKnob/10.) ! final Q (gpm)
- data%State%Choke%Cumulative_AirVolume_Choke= data%State%Choke%Cumulative_AirVolume_Choke + ((data%State%AirDrivenPump%QAIR_PUMP * data%State%AirPumpLine%DeltaT_Choke / 60.0 ) / (1.5*0.004329004) ) ! =strokes
-
- if ( data%State%Choke%Cumulative_AirVolume_Choke > 1.0 ) then
- data%State%Choke%SoundChokePump= 60
- data%State%Choke%Cumulative_AirVolume_Choke= data%State%Choke%Cumulative_AirVolume_Choke - 1.0
- else
- data%State%Choke%SoundChokePump= 0.0
- endif
- data%State%AirPumpLine%DELTAV_AIR=data%State%AirDrivenPump%QAIR_PUMP*data%State%AirPumpLine%DeltaT_Choke/60 !(galon) delta_t=1sec , Q(gpm)
- if (data%State%CHOOKE(CHNUMBER)%ChokeIsClosing) data%State%CHOOKE(CHNUMBER)%PassedCourse=data%State%CHOOKE(CHNUMBER)%PassedCourse + (data%State%AirPumpLine%DELTAV_AIR*3785.412/data%State%AirPumpLine%Acylinder)!*(ChokeRateControlKnob/10.) ! 3785.412 : GALON TO CM^3
- if (data%State%CHOOKE(CHNUMBER)%ChokeIsOpening) data%State%CHOOKE(CHNUMBER)%PassedCourse=data%State%CHOOKE(CHNUMBER)%PassedCourse - (data%State%AirPumpLine%DELTAV_AIR*3785.412/data%State%AirPumpLine%Acylinder)!*(ChokeRateControlKnob/10.)
- !DeltaT_Choke= 1sec or 2sec
- !((((((((IN OUTER LOOP))))))
- !===============AIR PUMP OUTPUTS=========================
- data%State%AirPumpLine%alpha_timeair=data%State%AirPumpLine%TIME ! overal time (s)
- data%State%AirPumpLine%alpha_Pdownstrem=data%State%AirPumpLine%Pdownstrem
- data%State%AirPumpLine%alpha_pairp=data%State%AirPumpLine%P_AIRP
- data%State%AirPumpLine%alpha_Qair=data%State%AirDrivenPump%QAIR_PUMP
- !write(*,*) 'diffp_air=',diffp_air
- !pause
- data%State%AirPumpLine%alpha_diffpair=data%State%AirPumpLine%diffp_air
- data%State%AirPumpLine%alpha_lossesair=data%State%AirPumpLine%losses_air
- !========================================================
- !OPEN(150,FILE='CHOKE_AIRPUMP_OUTPUTS.DAT')
-
- if (data%State%CHOOKE(CHNUMBER)%ChokeIsClosing .AND. data%State%CHOOKE(CHNUMBER)%PassedCourse>data%State%AirPumpLine%CourseBase) then
- data%State%CHOOKE(CHNUMBER)%PassedCourse=data%State%AirPumpLine%CourseBase
- data%State%Choke%SoundChokePump= 0.0
- endif
- if (data%State%CHOOKE(CHNUMBER)%ChokeIsOpening .AND. data%State%CHOOKE(CHNUMBER)%PassedCourse<0.) then
- data%State%CHOOKE(CHNUMBER)%PassedCourse=0.
- data%State%Choke%SoundChokePump= 0.0
- endif
-
- call SetSoundChokePump(data%State%Choke%SoundChokePump)
- data%State%CHOOKE(CHNUMBER)%PercentClose= data%State%CHOOKE(CHNUMBER)%PassedCourse/data%State%AirPumpLine%CourseBase
- IF (data%Equipments%ChokeControlPanel%Choke1LED==1) THEN
- data%Equipments%ChokeControlPanel%ChokePosition= (1 - data%State%Choke%GaugeChokePositionMailf) * data%State%CHOOKE(1)%PercentClose*10
- ELSE ! Choke2LED==1
- data%Equipments%ChokeControlPanel%ChokePosition= (1 - data%State%Choke%GaugeChokePositionMailf) * data%State%CHOOKE(2)%PercentClose*10
- ENDIF
- !CALL SetHydraulicChock1(nint(MIN(data%State%CHOOKE(1)%PercentClose / 0.91 , 1.0)*100))
- ! CALL SetHydraulicChock2(nint(MIN(data%State%CHOOKE(2)%PercentClose / 0.91 , 1.0)*100))
- ! .91 >> 9 percent clearance
-
- ! =================== calculating Area
- ! AreaChoke=0.5
- ! .91 >> 9 percent clearance
-
- data%State%CHOOKE(1)%AreaChoke=0.01334635-(0.01334635* MIN(data%State%CHOOKE(1)%PercentClose / 0.91 , 1.0)) !ft^2 0.01334635 is ChokeAreaFullyOpen (ft^2)
- data%State%CHOOKE(2)%AreaChoke=0.01334635-(0.01334635* MIN(data%State%CHOOKE(2)%PercentClose/ 0.91 , 1.0)) !ft^2
- data%State%Choke%HydraulicChoke1WashoutCoef= data%State%Choke%HydraulicChoke1WashoutCoef * data%State%CHOOKE(1)%WashoutMalf
- data%State%Choke%HydraulicChoke1WashoutCoef= MIN( 0.5 , data%State%Choke%HydraulicChoke1WashoutCoef+ data%State%CHOOKE(1)%WashoutMalf*(0.5/(60.0/data%State%AirPumpLine%DeltaT_Choke)) ) ! 0.5=maximum washout coef , 60.0 sec= 1min duration time
- data%State%Choke%HydraulicChoke2WashoutCoef= data%State%Choke%HydraulicChoke2WashoutCoef * data%State%CHOOKE(2)%WashoutMalf
- data%State%Choke%HydraulicChoke2WashoutCoef= MIN( 0.5 , data%State%Choke%HydraulicChoke2WashoutCoef+ data%State%CHOOKE(2)%WashoutMalf*(0.5/(60.0/data%State%AirPumpLine%DeltaT_Choke)) ) ! 0.5=maximum washout coef , 60.0 sec= 1min duration time
- !write(*,*) 'HydraulicChoke1WashoutCoef=' , HydraulicChoke1WashoutCoef
-
- IF (data%State%CHOOKE(1)%PlugMalf == 1) THEN
- data%State%Choke%Present_HydraulicChoke1Plug= data%State%Choke%Present_HydraulicChoke1Plug * data%State%CHOOKE(1)%PlugMalf
- ! integer: HydraulicChoke1PluggedPercent,HydraulicChoke1PluggedPercent_Old,PlugTimeCounter,ChokePlugTimeDelay
- ! real: Present_HydraulicChoke1Plug,DeltaPlug1Percent
- !write(*,*) 'HydraulicChoke1PluggedPercent=' , HydraulicChoke1PluggedPercent
-
- if ( (data%problems%ChokeProblems%HydraulicChoke1PluggedPercent - data%State%Choke%HydraulicChoke1PluggedPercent_Old) /= 0) then
- data%State%Choke%DeltaPlug1Percent = (REAL(data%problems%ChokeProblems%HydraulicChoke1PluggedPercent)/100.) - data%State%Choke%Present_HydraulicChoke1Plug
- data%State%Choke%Plug1TimeCounter = 0
- !write(*,*) 'DeltaPlug1Percent, Present_HydraulicChoke1Plug = ' ,DeltaPlug1Percent , Present_HydraulicChoke1Plug
- endif
- data%State%Choke%Plug1TimeCounter= data%State%Choke%Plug1TimeCounter + 1
- data%State%Choke%HydraulicChoke1PluggedPercent_Old= data%problems%ChokeProblems%HydraulicChoke1PluggedPercent
-
- if (data%State%Choke%Plug1TimeCounter <= data%State%Choke%ChokePlugTimeDelay) then !ChokePlugTimeDelay=600
- data%State%Choke%Present_HydraulicChoke1Plug = data%State%Choke%Present_HydraulicChoke1Plug + data%State%CHOOKE(1)%PlugMalf* ((data%State%Choke%DeltaPlug1Percent / real(data%State%Choke%ChokePlugTimeDelay))) ! real(ChokePlugTimeDelay)= 600.0
- endif
- !write(*,*) 'Present_HydraulicChoke1Plug=' , Present_HydraulicChoke1Plug
- ENDIF
-
- IF (data%State%CHOOKE(2)%PlugMalf == 1) THEN
- data%State%Choke%Present_HydraulicChoke2Plug= data%State%Choke%Present_HydraulicChoke2Plug * data%State%CHOOKE(2)%PlugMalf
- ! integer: HydraulicChoke2PluggedPercent,HydraulicChoke2PluggedPercent_Old,PlugTimeCounter,ChokePlugTimeDelay
- ! real: Present_HydraulicChoke2Plug,DeltaPlug2Percent
- if ( (data%problems%ChokeProblems%HydraulicChoke2PluggedPercent - data%State%Choke%HydraulicChoke2PluggedPercent_Old) /= 0 ) then
- data%State%Choke%DeltaPlug2Percent = (REAL(data%problems%ChokeProblems%HydraulicChoke2PluggedPercent)/100.) - data%State%Choke%Present_HydraulicChoke2Plug
- data%State%Choke%Plug2TimeCounter = 0
- endif
- data%State%Choke%Plug2TimeCounter= data%State%Choke%Plug2TimeCounter + 1
- data%State%Choke%HydraulicChoke2PluggedPercent_Old= data%problems%ChokeProblems%HydraulicChoke2PluggedPercent
- if (data%State%Choke%Plug2TimeCounter <= data%State%Choke%ChokePlugTimeDelay) then !ChokePlugTimeDelay=600
- data%State%Choke%Present_HydraulicChoke2Plug = data%State%Choke%Present_HydraulicChoke2Plug + data%State%CHOOKE(2)%PlugMalf *((data%State%Choke%DeltaPlug2Percent / real(data%State%Choke%ChokePlugTimeDelay))) ! real(ChokePlugTimeDelay)= 600.0
- endif
- ENDIF
- ! fully open area is 123/64 in^2 = 0.01334635 ft^2
- data%State%CHOOKE(1)%AreaChoke=data%State%CHOOKE(1)%AreaChoke+(data%State%CHOOKE(1)%WashoutMalf*data%State%Choke%HydraulicChoke1WashoutCoef*data%State%Choke%ChokeAreaFullyOpen/144.0) ! Initialised in Choke Startup
-
- !write(*,*) 'data%State%CHOOKE(1)%WashoutMalf , data%State%CHOOKE(1)%AreaChoke=' ,data%State%CHOOKE(1)%WashoutMalf , data%State%CHOOKE(1)%AreaChoke
-
- data%State%CHOOKE(1)%AreaChoke=data%State%CHOOKE(1)%AreaChoke-(data%State%CHOOKE(1)%PlugMalf* data%State%Choke%Present_HydraulicChoke1Plug *data%State%CHOOKE(1)%AreaChoke) ! Initialised in Choke Startup
-
- data%State%CHOOKE(2)%AreaChoke=data%State%CHOOKE(2)%AreaChoke+(data%State%CHOOKE(2)%WashoutMalf*data%State%Choke%HydraulicChoke2WashoutCoef*data%State%Choke%ChokeAreaFullyOpen/144.0) ! Initialised in Choke Startup
- data%State%CHOOKE(2)%AreaChoke=data%State%CHOOKE(2)%AreaChoke-(data%State%CHOOKE(2)%PlugMalf* data%State%Choke%Present_HydraulicChoke2Plug *data%State%CHOOKE(2)%AreaChoke) ! Initialised in Choke Startup
- !write(*,*) 'data%State%CHOOKE(2)%WashoutMalf , data%State%CHOOKE(2)%AreaChoke=' ,data%State%CHOOKE(2)%WashoutMalf , data%State%CHOOKE(2)%AreaChoke
-
-
- data%State%CHOOKE(1)%AreaChokeFinal= data%State%CHOOKE(1)%AreaChoke
- data%State%CHOOKE(2)%AreaChokeFinal= data%State%CHOOKE(2)%AreaChoke
-
- ! 144: ft^2 to in^2
- CALL SetHydraulicChock1(100 - nint((data%State%CHOOKE(1)%AreaChokeFinal/(data%State%Choke%ChokeAreaFullyOpen/144.))*100)) ! for manifold valve
- CALL SetHydraulicChock2(100 - nint((data%State%CHOOKE(2)%AreaChokeFinal/(data%State%Choke%ChokeAreaFullyOpen/144.))*100)) ! for manifold valve
-
-
- !write(*,*) 'data%State%CHOOKE(1)%PercentClose=' , data%State%CHOOKE(1)%PercentClose ! close percent 0 to 100
- !write(*,*) 'ChokePosition=' , ChokePosition ! close position 0 to 10 for display
- !write(*,*) 'data%State%CHOOKE(1)%AreaChokeFinal=' , data%State%CHOOKE(1)%AreaChokeFinal ! Open Area (in^2) with clearance
- !write(*,*) '(ChokeAreaFullyOpen/144.)=' , (ChokeAreaFullyOpen/144.)
- !write(*,*) 'valve value=' , 100 - nint((data%State%CHOOKE(1)%AreaChokeFinal/(ChokeAreaFullyOpen/144.))*100) ! percent close 0 to 100 with clearance
- !write(*,*) 'Valve(33)%Status=' , Valve(33)%Status ! T : open , F: close
- ! =================== calculating Area
- !write(*,*) 'data%State%CHOOKE(1)%AreaChoke= ' , data%State%CHOOKE(1)%AreaChoke
- !WRITE(150,50) alpha_timeair,alpha_Qair,alpha_pairp, &
- !alpha_Pdownstrem,alpha_diffpair,alpha_lossesair,data%State%CHOOKE(CHNUMBER)%PassedCourse
- !50 FORMAT(7(f15.5))
- !========================================================================================
- !========================================================================================
- ! write(*,*) PassedCourse
- end
|