Simulation Core
Você não pode selecionar mais de 25 tópicos Os tópicos devem começar com uma letra ou um número, podem incluir traços ('-') e podem ter até 35 caracteres.
 
 
 
 
 
 

35 linhas
2.3 KiB

  1. # 1 "/home/admin/SimulationCore2/Equipments/Pumps/Pump_OnMode_Solver.f90"
  2. subroutine Pump_OnMode_Solver(Pump_No)
  3. use SimulationVariables
  4. IMPLICIT NONE
  5. INTEGER :: Pump_No
  6. data%State%Pump(Pump_No)%Flow_Rate = data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio) ![gpm]
  7. data%State%Pump(Pump_No)%Max_FlowRate = data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*data%State%Pump(Pump_No)%MaxSPM ![gpm]
  8. data%State%Pump(Pump_No)%HorsePower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%StandPipe_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
  9. !data%State%Pump(Pump_No)%Max_Horsepower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%Max_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
  10. data%State%Pump(Pump_No)%Max_Horsepower = (data%State%Pump(Pump_No)%Flow_Rate*data%State%Pump(Pump_No)%Max_Pressure)/(1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency)
  11. ! if ( data%State%Pump(Pump_No)%StandPipe_Pressure>data%State%Pump(Pump_No)%Max_Pressure ) then ! in shart check shavad
  12. ! !if ( (data%State%Pump(Pump_No)%StandPipe_Pressure*data%State%Pump(Pump_No)%Flow_Rate)>(1714.d0*data%State%Pump(Pump_No)%Max_Horsepower*data%State%Pump(Pump_No)%Mech_Efficiency) ) then
  13. ! data%State%Pump(Pump_No)%Flow_Rate = (1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency*data%State%Pump(Pump_No)%Max_Horsepower)/data%State%Pump(Pump_No)%StandPipe_Pressure ![gpm]
  14. ! data%State%Pump(Pump_No)%Speed = ( data%State%Pump(Pump_No)%Flow_Rate/(data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0) )*data%State%Pump(Pump_No)%Trans_Ratio ![rpm]
  15. ! end if
  16. data%State%Pump(Pump_No)%SoundSPM = INT(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio) ![SPM] ![spm]
  17. If (data%State%Pump(Pump_No)%Flow_Rate>0.d0) Then
  18. data%State%Pump(Pump_No)%Open_Close = 1
  19. Else
  20. data%State%Pump(Pump_No)%Open_Close = 0
  21. End if
  22. end subroutine Pump_OnMode_Solver