module BOP contains subroutine BopStack_Init call BOP_StartUp end subroutine BopStack_Init subroutine BopStack_Step use SimulationVariables use CBopControlPanel use BopVariables use SimulationVariables !@ ! USE CEquipmentsConstants use CSounds implicit none data%State%BopStackInput%BOP_timeCounter= data%State%BopStackInput%BOP_timeCounter + 1 write(*,*) 'BOP_timeCounter=' , data%State%BopStackInput%BOP_timeCounter data%EquipmentControl%BopControlPanel%AirSupplyPressureGauge= (1 - data%State%BopStackAcc%AirSupplyPressureGaugeMalf)* (1 - data%State%BopStackAcc%RigAirMalf) *120. !psi if (data%State%BopStackAcc%pram_reg < 2300.) then data%State%ShearRAM%ShearIsNotAllowed= 1 else data%State%ShearRAM%ShearIsNotAllowed= 0 endif !write(*,*) 'ShearIsNotAllowed=' , ShearIsNotAllowed !TD_AnnularFillingFinal ! (0.0 to 1.0) percentage filled by tool joint !====================================================================== ! MAIN BODY OF PROGRAM ! PURPOSE: BOP Control !====================================================================== !=== Instantaneous Pipe Diameters in Each Ram (Input from TD Module):== data%State%Annular%ODDrillpipe_inAnnular= data%State%TD_BOP%AnnularPreventerDiam * 12.0 ! ft to inch data%State%PipeRam1%ODDrillpipe_in= data%State%TD_BOP%UpperRamDiam * 12.0 data%State%ShearRAM%ODDrillpipe_inShearRam= data%State%TD_BOP%BlindRamDiam * 12.0 data%State%PipeRam2%ODDrillpipe_in= data%State%TD_BOP%LowerRamDiam * 12.0 !IDshearBopFinal !IDPipeRam1Final !IDPipeRam2Final !IDAnnularFinal data%State%ShearRAM%OpenArea_shearBop= PI*(data%State%ShearRAM%IDshearBopFinal**2-data%State%ShearRAM%ODDrillpipe_inShearRam**2)/4.0d0 !D(in), AREA(in^2) data%State%ShearRAM%OpenArea_PipeRam1= PI*(data%State%ShearRAM%IDPipeRam1Final**2-data%State%PipeRam1%ODDrillpipe_in**2)/4.0d0 !D(in), AREA(in^2) data%State%ShearRAM%OpenArea_PipeRam2= PI*(data%State%ShearRAM%IDPipeRam2Final**2-data%State%PipeRam2%ODDrillpipe_in**2)/4.0d0 !D(in), AREA(in^2) data%State%ShearRAM%OpenArea_Annular= PI*(data%State%ShearRAM%IDAnnularFinal**2-data%State%Annular%ODDrillpipe_inAnnular**2)/4.0d0 !D(in), AREA(in^2) data%State%ShearRAM%MinimumOpenArea_InBOP= min(data%State%ShearRAM%OpenArea_shearBop,data%State%ShearRAM%OpenArea_PipeRam1,data%State%ShearRAM%OpenArea_PipeRam2,data%State%ShearRAM%OpenArea_Annular) !TD_BOPConnectionPossibility(j) = 0 or 1 !!!AnnularPreventerDiam = TD_BOPConnectionPossibility(1) >> used in Annular code !!!UpperRamDiam = TD_BOPConnectionPossibility(2) >> used in PipeRam1 code !!!BlindRamDiam = TD_BOPConnectionPossibility(3) >> used in ShearRam code !!!LowerRamDiam = TD_BOPConnectionPossibility(4) >> used in PipeRam2 code !===================================================================== !============SEALING PRESSURES TO BE SET IN ANNULAR REGULATOR========== data%State%AnnularComputational%WellBorePressure=5000. if (data%State%Annular%ODDrillpipe_inAnnular>0.) then if (data%State%Annular%ODDrillpipe_inAnnular>0. .and. data%State%Annular%ODDrillpipe_inAnnular<=1.99) then data%State%AnnularComputational%acoef=-0.2673 data%State%AnnularComputational%Bcoef=994.3 data%State%AnnularComputational%const=77 elseif (data%State%Annular%ODDrillpipe_inAnnular>1.99 .and. data%State%Annular%ODDrillpipe_inAnnular<=2.375) then data%State%AnnularComputational%acoef=-0.2539 data%State%AnnularComputational%Bcoef=994.3 data%State%AnnularComputational%const=73.15 elseif (data%State%Annular%ODDrillpipe_inAnnular>2.375 .and. data%State%Annular%ODDrillpipe_inAnnular<=2.875) then data%State%AnnularComputational%acoef=-0.2005 data%State%AnnularComputational%Bcoef=745.9 data%State%AnnularComputational%const=57.75 elseif (data%State%Annular%ODDrillpipe_inAnnular>2.875 .and. data%State%Annular%ODDrillpipe_inAnnular<=3.5) then data%State%AnnularComputational%acoef=-0.1871 data%State%AnnularComputational%Bcoef=696.1 data%State%AnnularComputational%const=53.9 elseif (data%State%Annular%ODDrillpipe_inAnnular>3.5 .and. data%State%Annular%ODDrillpipe_inAnnular<=5) then data%State%AnnularComputational%acoef=-0.1733 data%State%AnnularComputational%Bcoef=647 data%State%AnnularComputational%const=50 elseif (data%State%Annular%ODDrillpipe_inAnnular>5 .and. data%State%Annular%ODDrillpipe_inAnnular<=10) then data%State%AnnularComputational%acoef=-0.1604 data%State%AnnularComputational%Bcoef=596.7 data%State%AnnularComputational%const=46.2 endif data%State%AnnularComputational%AnnularSealingPressure= max((data%State%AnnularComputational%acoef*data%State%AnnularComputational%WellBorePressure+data%State%AnnularComputational%Bcoef), data%State%AnnularComputational%const) !(psi) else !CSO(COMPLETE SHUT OFF) ODDrillpipe_inAnnular=0 data%State%AnnularComputational%AnnularSealingPressure= 1150. !(psi) endif !===================================================================== ! BYPASS POSITION !===================================================================== if(data%EquipmentControl%BopControlPanel%ByePassValve == -1.0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1) then data%State%BopStackAcc%ByPassOld= -1.0 !write(*,*) 'ByePassValve to -1' ,ByePassValve elseif(data%EquipmentControl%BopControlPanel%ByePassValve == 1.0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1) then data%State%BopStackAcc%ByPassOld= 1.0 !write(*,*) 'ByePassValve to 1=' ,ByePassValve endif !write(*,*) 'ByePassValve,ByPassOld=' ,ByePassValve,ByPassOld !===================================================================== !WRITE(*,*) 'AnnularRegulatorSetControl====' , AnnularRegulatorSetControl data%State%Annular%Pannular_regset=min(data%EquipmentControl%BopControlPanel%AnnularRegulatorSetControl,1700.) ! for changing its set conditions instantaneously if (data%State%Annular%Annular_closed==1) then if (data%State%Annular%FirstSet==1) then ! code start data%State%Annular%Pannular_reg= data%State%Annular%Pannular_regset endif if (data%State%Annular%FirstSet==0) then ! durig run, but annular is not closing or opening data%State%Annular%Pannular_reg= min(data%State%RamLine%P_ACC,data%State%Annular%Pannular_regset) endif endif !=================================================================== ! Annular Preventer Pressure Rise On Tooljoint !=================================================================== if ( data%State%Annular%Annular_Situation_forTD == 1 .and. data%State%TD_BOP%AnnularFillingFinal==0.0 ) then ! Annular_Situation_forTD= 1 ! closed - for TD code data%State%AnnularComputational%AnnPressureRise= .true. elseif ( data%State%Annular%Annular_Situation_forTD == 0 ) then data%State%AnnularComputational%AnnPressureRise= .false. endif if (data%State%AnnularComputational%AnnPressureRise == .true.) then data%State%Annular%Pannular_reg= data%State%Annular%Pannular_reg + 200. * data%State%TD_BOP%AnnularFillingFinal ! 200 psi pressure rise when 100% of AnnPreventer is filled by tool joint !TD_AnnularFillingFinal ! (0.0 to 1.0) percentage filled by tool joint endif !=================================================================== if (data%State%Annular%FirstSet== 1) then !new= (1 - AnnularPressureGaugeMalf) * min(AnnularRegulatorSetControl,1700.) CALL data%State%AnnularComputational%Pannular_regDelay%AddToFirst( (1 - data%State%Annular%AnnularPressureGaugeMalf) * min(data%EquipmentControl%BopControlPanel%AnnularRegulatorSetControl,1700.) ) CALL data%State%AnnularComputational%Pannular_regDelay%Remove(data%State%AnnularComputational%Pannular_regDelay%Length()) data%EquipmentControl%BopControlPanel%AnnularPressureGauge= data%State%AnnularComputational%Pannular_regDelay%Last() !AnnularPressureGauge= (1 - AnnularPressureGaugeMalf) * min(AnnularRegulatorSetControl,1700.) !write(*,*) 'set 1' , AnnularPressureGauge else !FirstSet== 0 !new= (1 - AnnularPressureGaugeMalf) * Pannular_reg CALL data%State%AnnularComputational%Pannular_regDelay%AddToFirst( (1 - data%State%Annular%AnnularPressureGaugeMalf) * data%State%Annular%Pannular_reg) CALL data%State%AnnularComputational%Pannular_regDelay%Remove(data%State%AnnularComputational%Pannular_regDelay%Length()) data%EquipmentControl%BopControlPanel%AnnularPressureGauge= data%State%AnnularComputational%Pannular_regDelay%Last() !AnnularPressureGauge= (1 - AnnularPressureGaugeMalf) * Pannular_reg !write(*,*) 'set 0' , AnnularPressureGauge endif !=================================================== ! AIR OPERATED PUMP CODE- START !=================================================== if (data%State%RamLine%P_ACCdata%State%Pumps%AIR_OFF .and. data%State%RamLine%AIRP_SWITCH==1) then data%State%RamLine%AIRP_SWITCH=0 call SetSoundKoomeyAirPump(data%State%RamLine%AIRP_SWITCH) endif if (data%State%RamLine%P_ACCdata%State%Pumps%ELECTRIC_OFF .and. data%State%RamLine%ELECP_SWITCH==1) then data%State%RamLine%ELECP_SWITCH=0 endif !write(*,*) 'airp_switch,elecp_switch=' , airp_switch,elecp_switch !================CHARGING BOTTLES======================= if (data%State%RamLine%AIRP_SWITCH==1 .or. data%State%RamLine%ELECP_SWITCH==1) then if (data%State%Annular%Annular_closed==1 .and. data%State%RamLine%ShearBop_closed==1 .and. data%State%PipeRam1%closed==1 .and. data%State%PipeRam2%closed==1 .and. data%State%ChokeLine%closed==1 .and. data%State%KillLine%closed==1) then call pumps_charge_bottle() ! increases volume and pressure in the bottles if (data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_ChargedPressure) then data%State%RamLine%P_ACC=data%State%BopStackAcc%acc_ChargedPressure if (data%State%Annular%AnnularLeakMalf== 0) then !finished_Annular=1 data%State%RAM(1)%Bottles_Charged_MalfActive= .false. else data%State%Annular%finished_Annular=0 data%State%RAM(1)%Bottles_Charged_MalfActive= .true. !fvr=fvr-2.5 endif if (data%State%PipeRam1%UpperRamsLeakMalf== 0) then !finished_pipe1=1 data%State%RAM(2)%Bottles_Charged_MalfActive= .false. else data%State%PipeRam1%finished=0 data%State%RAM(2)%Bottles_Charged_MalfActive= .true. !fvr=fvr-2.5 endif if (data%State%PipeRam2%LowerRamsLeakMalf== 0) then !finished_pipe2=1 data%State%RAM(3)%Bottles_Charged_MalfActive= .false. else data%State%PipeRam2%finished=0 data%State%RAM(3)%Bottles_Charged_MalfActive= .true. !fvr=fvr-2.5 endif if (data%State%ShearRAM%MiddleRamsLeakMalf== 0) then !finished_shear=1 data%State%RAM(4)%Bottles_Charged_MalfActive= .false. else data%State%RamLine%FINISHED_shear=0 data%State%RAM(4)%Bottles_Charged_MalfActive= .true. !fvr=fvr-2.5 endif data%State%KillLine%finished=1 data%State%ChokeLine%finished=1 if (data%State%Annular%AnnularLeakMalf== 0 .and. data%State%PipeRam1%UpperRamsLeakMalf== 0 .and. data%State%PipeRam2%LowerRamsLeakMalf== 0 .and. data%State%ShearRAM%MiddleRamsLeakMalf== 0) then data%State%RamLine%ELECP_SWITCH=0 data%State%RamLine%AIRP_SWITCH=0 endif endif endif endif !======================================================= if (data%State%RamLine%ELECP_SWITCH==1 .and. data%State%BopStackAcc%AccPupmsFailMalf==0) then !on position data%State%Pumps%DELTAV_ELECP=data%State%Pumps%QELECTRIC*data%State%RamLine%DeltaT_BOP/60. !QELECTRIC_PUMP(gpm), deltav_elecp(gal), DeltaT_BOP(0.1 sec) data%State%Pumps%SoundKoomeyElectric= .True. else data%State%Pumps%DELTAV_ELECP=0 data%State%Pumps%SoundKoomeyElectric= .false. endif !call SetSoundKoomeyElectricPump(SoundKoomeyElectricPump) if (data%State%RamLine%AIRP_SWITCH==1 .and. data%State%BopStackAcc%AccPupmsFailMalf==0) then !on position call airpump_code() !ramtype=2 end if ! if (airp_switch==1) then !on position !===============AIR OPERATED PUMP CODE- END================ if (data%State%RamLine%ShearBop_closed==1 .and. data%State%PipeRam1%closed==1 .and. data%State%PipeRam2%closed==1 .and. data%State%ChokeLine%closed==1 .and. data%State%KillLine%closed==1) then !write(*,*) ' All Rams are closed' if(data%State%BopStackAcc%ByPassOld== -1.0) then ! (OPEN POSITION) !old=pram_reg !new=p_acc- MAXVAL(data%State%RAM%loss_before) !difference= new-old data%State%BopStackAcc%PressureDifference= data%State%RamLine%P_ACC- MAXVAL(data%State%RAM%loss_before) - data%State%BopStackAcc%pram_reg if (ABS(data%State%BopStackAcc%PressureDifference) > BaseDifferenceP) then !BaseDifferenceP= 300. psi data%State%BopStackAcc%pram_reg= data%State%BopStackAcc%pram_reg + (data%State%BopStackAcc%PressureDifference/PressureDifferenceSteps) ! PressureDifferenceSteps = 20. else data%State%BopStackAcc%pram_reg= data%State%RamLine%P_ACC- MAXVAL(data%State%RAM%loss_before) ! mishe khate paeen ye shart gozasht ke pacc=3000 shod, in adad dige kam nashe endif elseif (data%State%BopStackAcc%ByPassOld== 1.0) then ! (CLOSE POSITION) !pram_reg= prams_regset !if (RamsFirstSet==1) then !write(*,*) 'bypass CLOSE POSITION' !old=pram_reg !new=prams_regset !difference= new-old data%State%BopStackAcc%PressureDifference= data%State%BopStackAcc%PRAMS_REGSET - data%State%BopStackAcc%pram_reg !write(*,*) 'PressureDifference, prams_regset , pram_reg=' , PressureDifference, prams_regset , pram_reg if (ABS(data%State%BopStackAcc%PressureDifference) > BaseDifferenceP) then !BaseDifferenceP= 200. ! psi in starup data%State%BopStackAcc%pram_reg= data%State%BopStackAcc%pram_reg + (data%State%BopStackAcc%PressureDifference/PressureDifferenceSteps) ! PressureDifferenceSteps = 20. in startup else data%State%BopStackAcc%pram_reg= data%State%BopStackAcc%PRAMS_REGSET endif !write(*,*) 'pram_reg=' , pram_reg !endif ! if (RamsFirstSet==1) then endif endif data%EquipmentControl%BopControlPanel%MiddleRamsStatus = data%State%ShearRAM%IDshearBop data%EquipmentControl%BopControlPanel%UpperRamsStatus = data%State%PipeRam1%ID data%EquipmentControl%BopControlPanel%LowerRamsStatus = data%State%PipeRam2%ID data%EquipmentControl%BopControlPanel%AnnularStatus = data%State%Annular%IDAnnular data%EquipmentControl%BopControlPanel%AccumulatorPressureGauge = (1 - data%State%BopStackAcc%AccumulatorPressureGaugeMalf) * data%State%RamLine%P_ACC data%EquipmentControl%BopControlPanel%ManifoldPressureGauge= (1 - data%State%BopStackAcc%ManifoldPressureGaugeMalf) * data%State%BopStackAcc%pram_reg !AnnularPressureGauge=Pannular_reg ! ! WRITE(60,60) data%State%RAM(2)%time,data%State%RAM(2)%Q,data%State%RAM(2)%vdis_tot,p_acc, & ! pram_reg,Pannular_reg,data%State%RAM(2)%p_bop,IDshearBop, & ! IDPipeRam1,IDPipeRam2,IDAnnular !60 FORMAT(11(f18.5)) !WRITE(*,*) 'IDAnnular=' , IDAnnular !write(*,*) 'elecp_switch=' , elecp_switch !call sleepqq(100) end subroutine BopStack_Step end module BOP