SUBROUTINE PIPE_RAMS2 use SimulationVariables USE CBopStackVariables use CBopControlPanel use SimulationVariables USE CEquipmentsConstants ! ! use CSimulationVariables implicit none !write(*,*) 'checkpoint 1' !===================================================================== ! PIPE RAMS 2- BOP CAMERON Type U 5000 ! START CONDITIONS FOR PIPE RAMS 2 !===================================================================== data%State%RAM(3)%SuccessionCounter = data%State%RAM(3)%SuccessionCounter + 1 if (data%Equipments%BopControlPanel%LowerRamsValve == 1.0 .and. data%State%PipeRam2%LowerRamsFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%Equipments%BopControlPanel%AirMasterValve==1) then !write(*,*) 'close 1' if (data%State%BopStackInput%LowerRamsCloseLEDMine == LedOn) then RETURN end if if ( data%State%RAM(3)%SuccessionCounter /= data%State%RAM(3)%SuccessionCounterOld+1 ) then data%State%RAM(3)%SuccessionCounter = 0 ! also in starup data%State%RAM(3)%SuccessionCounterOld = 0 ! also in starup !return else data%State%RAM(3)%SuccessionCounterOld= data%State%RAM(3)%SuccessionCounter endif if ( data%State%RAM(3)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then !return data%State%RAM(3)%First_CloseTimecheck= 1 data%Equipments%BopControlPanel%LowerRamsOpenLED = LedOff data%State%BopStackInput%LowerRamsOpenLEDMine = LedOff data%Equipments%BopControlPanel%LowerRamsCloseLED = LedOn !LedBlinking data%State%RAM(3)%FourwayValve = 1 endif endif if (data%State%RAM(3)%FourwayValve == 1 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure) then ! 1: Open , 0: Close !write(*,*) 'close 2' data%State%RAM(3)%FourwayValve = 0 data%State%PipeRam2%closed=0 !PipeRam2_closed_withPossibility= PipeRam2_closed * TD_BOPConnectionPossibility(4) data%State%RAM(3)%vdis_tot=0 data%State%RAM(3)%vdis_bottles=0. data%State%RAM(3)%fvr_air=0. data%State%RAM(3)%vdis_elecp=0. data%State%Pumps%Qiter=7 data%State%RAM(3)%Qzero=70 data%State%RAM(3)%Q=data%State%RAM(3)%Qzero data%State%RAM(3)%flow=70 data%State%RAM(3)%tol=0.0037 if (data%State%PipeRam2%finished==1) then data%State%PipeRam2%LeverOld=-1.0 else data%State%PipeRam2%LeverOld=data%Equipments%BopControlPanel%LowerRamsValve endif data%State%PipeRam2%finished=0 data%State%PipeRam2%IsClosing = .true. data%State%PipeRam2%IsOpening = .false. data%State%RAM(3)%bop_type = 3 !AbopPipeRam=196.67 data%State%PipeRam1%A=(data%Configuration%BopStack%LowerRamClose*231)/((data%State%PipeRam1%IDBase-data%State%PipeRam1%ODDrillpipe_inBase)/2.) data%State%PipeRam2%NeededVolume=data%State%PipeRam1%A*(data%State%PipeRam1%IDBase-max(data%State%PipeRam2%ODDrillpipe_in,data%State%PipeRam1%ODDrillpipe_inBase))/(2.*231) !galon for each BOP !write(*,*) 'close 1' endif if (data%Equipments%BopControlPanel%LowerRamsValve == -1.0 .and. data%State%PipeRam2%LowerRamsFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%Equipments%BopControlPanel%AirMasterValve==1) then !write(*,*) 'open 1' if (data%State%BopStackInput%LowerRamsOpenLEDMine == LedOn) then RETURN end if if ( data%State%RAM(3)%SuccessionCounter /= data%State%RAM(3)%SuccessionCounterOld+1 ) then data%State%RAM(3)%SuccessionCounter = 0 ! also in starup data%State%RAM(3)%SuccessionCounterOld = 0 ! also in starup !return else data%State%RAM(3)%SuccessionCounterOld= data%State%RAM(3)%SuccessionCounter endif if ( data%State%RAM(3)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then !return data%State%RAM(3)%First_OpenTimecheck= 1 data%Equipments%BopControlPanel%LowerRamsCloseLED = LedOff !new data%State%BopStackInput%LowerRamsCloseLEDMine = LedOff !new data%Equipments%BopControlPanel%LowerRamsOpenLED = LedOn !LedBlinking data%State%RAM(3)%FourwayValve = 1 endif endif if (data%State%RAM(3)%FourwayValve == 1 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure) then ! 1: Open , 0: Close !write(*,*) 'open 2' data%State%RAM(3)%FourwayValve = 0 data%State%PipeRam2%closed=0 !PipeRam2_closed_withPossibility= PipeRam2_closed * TD_BOPConnectionPossibility(4) data%State%RAM(3)%vdis_tot=0 data%State%RAM(3)%vdis_bottles=0. data%State%RAM(3)%fvr_air=0. data%State%RAM(3)%vdis_elecp=0. data%State%Pumps%Qiter=7 data%State%RAM(3)%Qzero=70 data%State%RAM(3)%Q=data%State%RAM(3)%Qzero data%State%RAM(3)%flow=70 data%State%RAM(3)%tol=0.0037 if (data%State%PipeRam2%finished==1) then data%State%PipeRam2%LeverOld=1.0 else data%State%PipeRam2%LeverOld=data%Equipments%BopControlPanel%LowerRamsValve endif data%State%PipeRam2%finished=0 data%State%PipeRam2%IsOpening = .true. data%State%PipeRam2%IsClosing = .false. !if (LowerRamsOpenLED == LedOn) then ! RETURN !end if data%State%RAM(3)%bop_type = 3 !AbopPipeRam=186.5 data%State%PipeRam1%A=(data%Configuration%BopStack%LowerRamOpen*231)/((data%State%PipeRam1%IDBase-data%State%PipeRam1%ODDrillpipe_inBase)/2.) data%State%PipeRam2%NeededVolume=data%State%PipeRam1%A*(data%State%PipeRam1%IDBase-max(data%State%PipeRam2%ODDrillpipe_in,data%State%PipeRam1%ODDrillpipe_inBase))/(2.*231) !galon for each BOP !write(*,*) 'open 1' endif !===================================================================== if (data%State%PipeRam2%IsOpening .or. data%State%PipeRam2%IsClosing .or. data%State%RAM(3)%Bottles_Charged_MalfActive) then data%State%Annular%FirstSet= 0 data%State%AnnularComputational%RamsFirstSet= 0 CALL PIPE_RAMS2_SUB end if END SUBROUTINE PIPE_RAMS2 SUBROUTINE PIPE_RAMS2_SUB use SimulationVariables USE CBopStackVariables use CBopControlPanel use SimulationVariables USE CEquipmentsConstants ! use CSimulationVariables implicit none ! FirstSet= 0 ! RamsFirstSet= 0 ! loop4: do while (finished_pipe2==0) !write(*,*) 'checkpoint 2' data%State%RAM(3)%SuccessionCounter = data%State%RAM(3)%SuccessionCounter + 1 if (data%Equipments%BopControlPanel%LowerRamsValve == 1.0 .and. data%State%PipeRam2%LeverOld == -1.0 .and. data%State%PipeRam2%LowerRamsFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%Equipments%BopControlPanel%AirMasterValve==1) then !write(*,*) 'close 3' if ( data%State%RAM(3)%First_CloseTimecheck == 0 ) then if ( data%State%RAM(3)%SuccessionCounter /= data%State%RAM(3)%SuccessionCounterOld+1 ) then data%State%RAM(3)%SuccessionCounter = 0 ! also in starup data%State%RAM(3)%SuccessionCounterOld = 0 ! also in starup !return else data%State%RAM(3)%SuccessionCounterOld= data%State%RAM(3)%SuccessionCounter endif if ( data%State%RAM(3)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then !return data%Equipments%BopControlPanel%LowerRamsOpenLED = LedOff data%State%BopStackInput%LowerRamsOpenLEDMine = LedOff data%Equipments%BopControlPanel%LowerRamsCloseLED = LedOn !LedBlinking data%State%RAM(3)%FourwayValve = 1 endif endif endif if (data%State%RAM(3)%FourwayValve == 1 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure) then !write(*,*) 'close 4' data%State%RAM(3)%FourwayValve = 0 data%State%PipeRam2%closed=0 !PipeRam2_closed_withPossibility= PipeRam2_closed * TD_BOPConnectionPossibility(4) data%State%RAM(3)%p_bop=data%State%ShearRAM%PA data%State%PipeRam2%LeverOld = data%Equipments%BopControlPanel%LowerRamsValve CALL OpenLowerRams data%State%PipeRam2%Situation_forTD= 0 ! open - for TD code data%State%RAM(3)%bop_type = 3 !AbopPipeRam=196.67 data%State%PipeRam1%A=(data%Configuration%BopStack%LowerRamClose*231)/((data%State%PipeRam1%IDBase-data%State%PipeRam1%ODDrillpipe_inBase)/2.) data%State%PipeRam2%NeededVolume=data%State%PipeRam1%A*(data%State%PipeRam2%ID-max(data%State%PipeRam2%ODDrillpipe_in,data%State%PipeRam1%ODDrillpipe_inBase))/(2.*231) data%State%RAM(3)%vdis_bottles=0. data%State%RAM(3)%fvr_air=0. data%State%RAM(3)%vdis_elecp=0. data%State%PipeRam2%IsClosing = .true. data%State%PipeRam2%IsOpening = .false. !write(*,*) 'close 2' endif if (data%Equipments%BopControlPanel%LowerRamsValve == -1.0 .and. data%State%PipeRam2%LeverOld == 1.0 .and. data%State%PipeRam2%LowerRamsFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%Equipments%BopControlPanel%AirMasterValve==1) then !write(*,*) 'open 3' if ( data%State%RAM(3)%First_OpenTimecheck == 0 ) then if ( data%State%RAM(3)%SuccessionCounter /= data%State%RAM(3)%SuccessionCounterOld+1 ) then data%State%RAM(3)%SuccessionCounter = 0 ! also in starup data%State%RAM(3)%SuccessionCounterOld = 0 ! also in starup !return else data%State%RAM(3)%SuccessionCounterOld= data%State%RAM(3)%SuccessionCounter endif if ( data%State%RAM(3)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then !return data%Equipments%BopControlPanel%LowerRamsCloseLED = LedOff data%State%BopStackInput%LowerRamsCloseLEDMine = LedOff data%Equipments%BopControlPanel%LowerRamsOpenLED = LedOn !LedBlinking data%State%RAM(3)%FourwayValve = 1 endif endif endif if (data%State%RAM(3)%FourwayValve == 1 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure) then !write(*,*) 'open 4' data%State%RAM(3)%FourwayValve = 0 data%State%PipeRam2%closed=0 !PipeRam2_closed_withPossibility= PipeRam2_closed * TD_BOPConnectionPossibility(4) data%State%RAM(3)%p_bop=data%State%ShearRAM%PA data%State%PipeRam2%LeverOld = data%Equipments%BopControlPanel%LowerRamsValve CALL OpenLowerRams data%State%PipeRam2%Situation_forTD= 0 ! open - for TD code data%State%RAM(3)%bop_type = 3 !AbopPipeRam=186.5 data%State%PipeRam1%A=(data%Configuration%BopStack%LowerRamOpen*231)/((data%State%PipeRam1%IDBase-data%State%PipeRam1%ODDrillpipe_inBase)/2.) data%State%PipeRam2%NeededVolume=data%State%PipeRam1%A*(data%State%PipeRam1%IDBase-data%State%PipeRam2%ID)/(2.*231) data%State%RAM(3)%vdis_bottles=0. data%State%RAM(3)%fvr_air=0. data%State%RAM(3)%vdis_elecp=0. data%State%PipeRam2%IsOpening = .true. data%State%PipeRam2%IsClosing = .false. !write(*,*) 'open 2' endif data%State%RAM(3)%First_CloseTimecheck = 0 data%State%RAM(3)%First_OpenTimecheck = 0 data%State%RAM(3)%time=data%State%RAM(3)%time+data%State%RamLine%DeltaT_BOP !overal time (s) !=================================================== ! BOP !=================================================== if (data%State%PipeRam2%closed==0) then !bop closing !write(*,*) 'BOP code is called' call bop_code(3,data%State%PipeRam2%H_Bop,3) !ramtype=3 3=RNUMBER endif !bop is closing !================================================================ if (data%State%PipeRam2%closed==1) then data%State%RAM(3)%Q=0 !p_bop=pram_reg data%State%RAM(3)%p_bop=data%State%ShearRAM%PA data%State%RAMS%minloss(3,17)=0. !RNUMBER=3 endif data%State%RAM(3)%timecounter_ram=data%State%RAM(3)%timecounter_ram+1 ! MiddleRamsStatus = IDshearBop ! UpperRamsStatus = IDPipeRam1 ! LowerRamsStatus = IDPipeRam2 ! AnnularStatus = IDAnnular ! AccumulatorPressureGauge = p_acc ! ManifoldPressureGauge= pram_reg ! AnnularPressureGauge=Pannular_reg ! ! ! ! WRITE(60,60) data%State%RAM(3)%time,data%State%RAM(3)%Q,data%State%RAM(3)%vdis_tot,p_acc, & ! pram_reg,Pannular_reg,data%State%RAM(3)%p_bop,IDshearBop, & ! IDPipeRam1,IDPipeRam2,IDAnnular !60 FORMAT(11(f18.5)) ! call sleepqq(100) if (data%State%PipeRam2%closed==1) then ! if ((MiddleRamsValve==1. .and. MiddleRamsFailureMalf==0) .or. (MiddleRamsValve==-1.0 .and. MiddleRamsFailureMalf==0) .or. (UpperRamsValve==1. .and. UpperRamsFailureMalf==0) .or. (UpperRamsValve==-1.0 .and. UpperRamsFailureMalf==0) .or. (AnnularValve==1. .and. AnnularFailureMalf==0) .or. (AnnularValve==-1.0 .and. AnnularFailureMalf==0) .or. ChokeLineValve==1. .or. ChokeLineValve==-1.0 .or. KillLineValve==1. .or. KillLineValve==-1.0) then data%State%PipeRam2%finished=1 ! endif endif ! if (IsStopped == .true.) return ! end do loop4 !while finished_pipe2==0 if ( data%State%PipeRam2%finished==1 .and. data%State%RAM(3)%Bottles_Charged_MalfActive==.true.) then call bop_code(3,data%State%PipeRam2%H_Bop,3) !ramtype=3 3=RNUMBER ! call sleepqq(100) endif END SUBROUTINE PIPE_RAMS2_SUB