  1. subroutine Pump_OnMode_Solver(Pump_No)
  2. Use Pumps_VARIABLES
  3. IMPLICIT NONE
  4. INTEGER :: Pump_No
  5. PUMP(Pump_No)%Flow_Rate = PUMP(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*(PUMP(Pump_No)%Speed/PUMP(Pump_No)%Trans_Ratio) ![gpm]
  6. PUMP(Pump_No)%Max_FlowRate = PUMP(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*PUMP(Pump_No)%MaxSPM ![gpm]
  7. PUMP(Pump_No)%HorsePower = ((PUMP(Pump_No)%Flow_Rate/0.01d0)*PUMP(Pump_No)%StandPipe_Pressure)/(168067.d0*PUMP(Pump_No)%Mech_Efficiency) ![HHP]
  8. !PUMP(Pump_No)%Max_Horsepower = ((PUMP(Pump_No)%Flow_Rate/0.01d0)*PUMP(Pump_No)%Max_Pressure)/(168067.d0*PUMP(Pump_No)%Mech_Efficiency) ![HHP]
  9. PUMP(Pump_No)%Max_Horsepower = (PUMP(Pump_No)%Flow_Rate*PUMP(Pump_No)%Max_Pressure)/(1714.d0*PUMP(Pump_No)%Mech_Efficiency)
  10. if ( PUMP(Pump_No)%StandPipe_Pressure>PUMP(Pump_No)%Max_Pressure ) then ! in shart check shavad
  11. !if ( (PUMP(Pump_No)%StandPipe_Pressure*PUMP(Pump_No)%Flow_Rate)>(1714.d0*PUMP(Pump_No)%Max_Horsepower*PUMP(Pump_No)%Mech_Efficiency) ) then
  12. PUMP(Pump_No)%Flow_Rate = (1714.d0*PUMP(Pump_No)%Mech_Efficiency*PUMP(Pump_No)%Max_Horsepower)/PUMP(Pump_No)%StandPipe_Pressure ![gpm]
  13. PUMP(Pump_No)%Speed = ( PUMP(Pump_No)%Flow_Rate/(PUMP(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0) )*PUMP(Pump_No)%Trans_Ratio ![rpm]
  14. end if
  15. PUMP(Pump_No)%SoundSPM = INT(PUMP(Pump_No)%Speed/PUMP(Pump_No)%Trans_Ratio) ![spm]
  16. If (PUMP(Pump_No)%Flow_Rate>0.d0) Then
  17. PUMP(Pump_No)%Open_Close = 1
  18. Else
  19. PUMP(Pump_No)%Open_Close = 0
  20. End if
  21. end subroutine Pump_OnMode_Solver