- subroutine Pumps_StartUp
- use CPumpsVariables
- use CPumps
- use SimulationVariables
- IMPLICIT NONE
- !>>>>>>>>>>>>>>>>>>>>>>> PUMP 1 <<<<<<<<<<<<<<<<<<<<<<<<<<<
- data%State%Pump(1)%FlowRatePerSTK = .04d0 ![bbl] !??????? motaghayere voroudi
- !data%State%Pump(1)%FlowRatePerSTK = data%State%Pump(1)%FlowRatePerSTK*0.0292d0 ![gpm]
- data%State%Pump(1)%RateChange = 4.d0 ![stk/min2 ??] !??????? motaghayere voroudi
- data%State%Pump(1)%Mech_Efficiency = data%Configuration%Pumps%MudPump1MechanicalEfficiency ![dimensionless]
- !data%State%Pump(1)%Vol_Efficiency = MudPump1VolumetricEfficiency !bayad hazf beshe ?
- data%State%Pump(1)%Max_Pressure = 6000.d0 ![psi] !??????? motaghayere voroudi
- data%State%Pump(1)%MaxSPM = data%Configuration%Pumps%MudPump1Maximum ![spm]
- data%State%Pump(1)%Trans_Ratio = 965.d0/data%State%Pump(1)%MaxSPM
- data%State%Pump(1)%time_step = 0.1d0 !?????? niaz hast ya na??
-
- data%State%Pump(1)%RateChange = 193.d0!data%State%Pump(1)%RateChange*data%State%Pump(1)%Trans_Ratio ! [rpm/min ??] ??????????????? rpm/s
- data%State%Pump(1)%K_throttle = 0
- data%State%Pump(1)%N_old = 0.d0
- Call Pump_OffMode_Solver(1)
- !>>>>>>>>>>>>>>>>>>>>>>> PUMP 2 <<<<<<<<<<<<<<<<<<<<<<<<<<<
- data%State%Pump(2)%FlowRatePerSTK = .04d0 ![bbl] !??????? motaghayere voroudi
- !data%State%Pump(2)%FlowRatePerSTK = data%State%Pump(2)%FlowRatePerSTK*0.0292d0 ![gpm]
- data%State%Pump(2)%RateChange = 4.d0 ![stk/min2 ??] !??????? motaghayere voroudi
- data%State%Pump(2)%Mech_Efficiency = data%Configuration%Pumps%MudPump2MechanicalEfficiency ![dimensionless]
- !data%State%Pump(2)%Vol_Efficiency = MudPump2VolumetricEfficiency !bayad hazf beshe ?
- data%State%Pump(2)%Max_Pressure = 6000.d0 ![psi] !??????? motaghayere voroudi
- data%State%Pump(2)%MaxSPM = data%Configuration%Pumps%MudPump2Maximum ![spm]
- data%State%Pump(2)%Trans_Ratio = 965.d0/data%State%Pump(2)%MaxSPM
- data%State%Pump(2)%time_step = 0.1d0 !?????? niaz hast ya na??
- data%State%Pump(2)%RateChange = 193.d0!data%State%Pump(2)%RateChange*data%State%Pump(2)%Trans_Ratio ! [rpm/min ??] ??????????????? rpm/s
- data%State%Pump(2)%K_throttle = 0
- data%State%Pump(2)%N_old = 0.d0
- Call Pump_OffMode_Solver(2)
- !!>>>>>>>>>>>>>>>>>>>>>>> PUMP 3 <<<<<<<<<<<<<<<<<<<<<<<<<<<
- data%State%Pump(3)%FlowRatePerSTK = .04d0 ![bbl] !??????? motaghayere voroudi
- !data%State%Pump(3)%FlowRatePerSTK = data%State%Pump(3)%FlowRatePerSTK*0.0292d0 ![gpm]
- data%State%Pump(3)%RateChange = 4.d0 ![stk/min2 ??] !??????? motaghayere voroudi
- data%State%Pump(3)%Mech_Efficiency = data%Configuration%Pumps%CementPumpMechanicalEfficiency ![dimensionless]
- !data%State%Pump(3)%Vol_Efficiency = CementPumpVolumetricEfficiency !bayad hazf beshe ?
- data%State%Pump(3)%Max_Pressure = 6000.d0 ![psi] !??????? motaghayere voroudi
- data%State%Pump(3)%MaxSPM = data%Configuration%Pumps%CementPumpMaximum ![spm]
- data%State%Pump(3)%Trans_Ratio = 965.d0/data%State%Pump(3)%MaxSPM
- data%State%Pump(3)%time_step = 0.1d0 !?????? niaz hast ya na??
- data%State%Pump(3)%RateChange = 193.d0!data%State%Pump(3)%RateChange*data%State%Pump(3)%Trans_Ratio ! [rpm/min ??] ??????????????? rpm/s
- data%State%Pump(3)%K_throttle = 0
- data%State%Pump(3)%N_old = 0.d0
- Call Pump_OffMode_Solver(3)
- end subroutine Pumps_StartUp
|