Simulation Core
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

ANNULAR.f90 14 KiB

1 jaar geleden
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427
  1. SUBROUTINE ANNULAR
  2. USE VARIABLES
  3. USE CBopControlPanelVariables
  4. USE PressureDisplayVARIABLES
  5. USE CEquipmentsConstants
  6. USE CBopStackVariables
  7. implicit none
  8. !write(*,*) 'checkpoint 1'
  9. !=====================================================================
  10. ! ANNULAR PREVENTER- BOP CAMERON Type U 5000
  11. ! START CONDITIONS FOR ANNULAR PREVENTER
  12. !=====================================================================
  13. RAM(1)%SuccessionCounter = RAM(1)%SuccessionCounter + 1
  14. if (AnnularValve == 1.0 .and. AnnularFailureMalf==0 .and. RigAirMalf==0 .and. AirMasterValve==1) then
  15. if (AnnularCloseLedMine == LedOn) then
  16. RETURN
  17. end if
  18. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  19. RAM(1)%SuccessionCounter = 0 ! also in starup
  20. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  21. !return
  22. else
  23. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  24. endif
  25. if ( RAM(1)%SuccessionCounter >= int(2.5/DeltaT_BOP) ) then
  26. !return
  27. RAM(1)%First_CloseTimecheck= 1
  28. AnnularOpenLed = LedOff
  29. AnnularOpenLedMine = LedOff
  30. AnnularCloseLed = LedOn !LedBlinking
  31. RAM(1)%FourwayValve = 1
  32. endif
  33. endif
  34. if (RAM(1)%FourwayValve == 1 .and. p_acc>acc_MinPressure .and. Pannular_reg>AnnularMovingPressure) then ! 1: Open , 0: Close
  35. RAM(1)%FourwayValve = 0
  36. Annular_closed=0
  37. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  38. RAM(1)%vdis_tot=0
  39. RAM(1)%vdis_bottles=0.
  40. RAM(1)%fvr_air=0.
  41. RAM(1)%vdis_elecp=0.
  42. Qiter=7
  43. RAM(1)%Qzero=70
  44. RAM(1)%Q=RAM(1)%Qzero
  45. RAM(1)%flow=70
  46. tolAnnular=0.0018
  47. if (finished_Annular==1) then
  48. AnnularLeverOld=-1.0
  49. else
  50. AnnularLeverOld=AnnularValve
  51. endif
  52. finished_Annular=0
  53. AnnularIsClosing = .true.
  54. AnnularIsOpening = .false.
  55. RAM(2)%bop_type = 3
  56. !AbopAnnular=963.1 !(in^2)
  57. AbopAnnular=(AnnularPreventerClose*231.)/((IDAnnularBase-ODDrillpipe_inAnnularBase)/2.) ! 231 in^3 = 1 gal
  58. NeededVolumeAnnular=AbopAnnular*(IDAnnularBase-max(ODDrillpipe_inAnnular,ODDrillpipe_inAnnularBase))/(2.*231) !=17.98 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnularBase=5
  59. !WRITE(*,*) 'a)NeededVolumeAnnular=' , NeededVolumeAnnular
  60. !write(*,*) 'close 1'
  61. endif
  62. if (AnnularValve == -1.0 .and. AnnularFailureMalf==0 .and. RigAirMalf==0 .and. AirMasterValve==1 ) then
  63. if (AnnularOpenLedMine == LedOn) then
  64. RETURN
  65. end if
  66. !CasingPressure : PressureGauges(2) *****temp conditionssssss
  67. !note: (AnnularSealingPressure) is only for opening while well is pressurised
  68. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  69. RAM(1)%SuccessionCounter = 0 ! also in starup
  70. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  71. !return
  72. else
  73. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  74. endif
  75. if ( RAM(1)%SuccessionCounter >= int(2.5/DeltaT_BOP) ) then
  76. !return
  77. RAM(1)%First_OpenTimecheck= 1
  78. AnnularCloseLed = LedOff !new
  79. AnnularCloseLedMine = LedOff !new
  80. AnnularOpenLed = LedOn !LedBlinking
  81. RAM(1)%FourwayValve = 1
  82. endif
  83. endif
  84. if (RAM(1)%FourwayValve == 1 .and. Pannular_reg>AnnularMovingPressure .and. p_acc>acc_MinPressure &
  85. .and. (Annular_closed==0 .or. (Annular_closed==1 .and.PressureGauges(2) <=100.0) .or. (Annular_closed==1 .and.PressureGauges(2)>100.0 .and. Pannular_reg>=AnnularSealingPressure))) then ! 1: Open , 0: Close
  86. !write(*,*) 'open 2'
  87. RAM(1)%FourwayValve = 0
  88. Annular_closed=0
  89. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  90. RAM(1)%vdis_tot=0
  91. RAM(1)%vdis_bottles=0.
  92. RAM(1)%fvr_air=0.
  93. RAM(1)%vdis_elecp=0.
  94. Qiter=7
  95. RAM(1)%Qzero=70
  96. RAM(1)%Q=RAM(1)%Qzero
  97. RAM(1)%flow=70
  98. tolAnnular=0.0018
  99. if (finished_Annular==1) then
  100. AnnularLeverOld=1.0
  101. else
  102. AnnularLeverOld=AnnularValve
  103. endif
  104. finished_Annular=0
  105. AnnularIsOpening = .true.
  106. AnnularIsClosing = .false.
  107. !if (AnnularOpenLed == LedOn) then
  108. ! RETURN
  109. !end if
  110. RAM(1)%bop_type = 3
  111. !AbopAnnular=758.48 !(in^2)
  112. AbopAnnular=(AnnularPreventerOpen*231)/((IDAnnularBase-max(ODDrillpipe_inAnnular,ODDrillpipe_inAnnularBase))/2.)
  113. NeededVolumeAnnular=AbopAnnular*(IDAnnularBase-ODDrillpipe_inAnnular)/(2.*231) !=14.16 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnular=5
  114. !write(*,*) 'open 1'
  115. endif
  116. !=====================================================================
  117. if (AnnularIsOpening .or. AnnularIsClosing .or. RAM(1)%Bottles_Charged_MalfActive) then
  118. CALL ANNULAR_SUB
  119. end if
  120. END SUBROUTINE ANNULAR
  121. SUBROUTINE ANNULAR_SUB
  122. USE VARIABLES
  123. USE PressureDisplayVARIABLES
  124. USE CBopControlPanelVariables
  125. USE CEquipmentsConstants
  126. USE CBopStackVariables
  127. USE CSimulationVariables
  128. implicit none
  129. FirstSet= 0
  130. RamsFirstSet= 0
  131. loop5: do while (finished_Annular==0)
  132. !write(*,*) 'checkpoint 2'
  133. RAM(1)%SuccessionCounter = RAM(1)%SuccessionCounter + 1
  134. ! CALL CPU_TIME(Annular_StartTime)
  135. if (AnnularValve == 1.0 .and. AnnularLeverOld == -1.0 .and. AnnularFailureMalf==0 .and. RigAirMalf==0 .and. AirMasterValve==1) then
  136. if ( RAM(1)%First_CloseTimecheck == 0 ) then
  137. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  138. RAM(1)%SuccessionCounter = 0 ! also in starup
  139. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  140. !return
  141. else
  142. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  143. endif
  144. if ( RAM(1)%SuccessionCounter >= int(2.5/DeltaT_BOP) ) then
  145. !return
  146. AnnularOpenLed = LedOff
  147. AnnularOpenLedMine = LedOff
  148. AnnularCloseLed = LedOn !LedBlinking
  149. RAM(1)%FourwayValve = 1
  150. endif
  151. endif
  152. !write(*,*) 'chekkk 1'
  153. endif
  154. if (RAM(1)%FourwayValve == 1 .and. Pannular_reg>AnnularMovingPressure .and. p_acc>acc_MinPressure) then
  155. !write(*,*) 'close 4'
  156. RAM(1)%FourwayValve = 0
  157. Annular_closed=0
  158. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  159. p_annular=pa_annular
  160. AnnularLeverOld = AnnularValve
  161. CALL OpenAnnular
  162. Annular_Situation_forTD= 0 ! open - for TD code
  163. RAM(1)%bop_type = 3
  164. !AbopAnnular=963.1 !(in^2)
  165. AbopAnnular=(AnnularPreventerClose*231)/((IDAnnularBase-ODDrillpipe_inAnnularBase)/2.)
  166. !write(*,*) 'NeededVolumeShearRams1=',NeededVolumeShearRams
  167. NeededVolumeAnnular=AbopAnnular*(IDAnnular-max(ODDrillpipe_inAnnular,ODDrillpipe_inAnnularBase))/(2*231.)
  168. ! write(*,*) 'NeededVolumeAnnular=',NeededVolumeAnnular
  169. RAM(1)%vdis_bottles=0.
  170. RAM(1)%fvr_air=0.
  171. RAM(1)%vdis_elecp=0.
  172. AnnularIsClosing = .true.
  173. AnnularIsOpening = .false.
  174. !write(*,*) 'close 2'
  175. endif
  176. if (AnnularValve == -1.0 .and. AnnularLeverOld == 1.0 .and. p_acc>acc_MinPressure .and. AnnularFailureMalf==0 .and. RigAirMalf==0 .and. AirMasterValve==1 ) then
  177. !CasingPressure : PressureGauges(2) *****temp conditionssssss
  178. !note: (AnnularSealingPressure) is only for opening while well is pressurised
  179. if ( RAM(1)%First_OpenTimecheck == 0 ) then
  180. if ( RAM(1)%SuccessionCounter /= RAM(1)%SuccessionCounterOld+1 ) then
  181. RAM(1)%SuccessionCounter = 0 ! also in starup
  182. RAM(1)%SuccessionCounterOld = 0 ! also in starup
  183. !return
  184. else
  185. RAM(1)%SuccessionCounterOld= RAM(1)%SuccessionCounter
  186. endif
  187. if ( RAM(1)%SuccessionCounter >= int(2.5/DeltaT_BOP) ) then
  188. !return
  189. AnnularCloseLed = LedOff
  190. AnnularCloseLedMine= LedOff
  191. AnnularOpenLed = LedOn !LedBlinking
  192. RAM(1)%FourwayValve = 1
  193. endif
  194. endif
  195. !write(*,*) 'chekkk 2'
  196. endif
  197. if (RAM(1)%FourwayValve == 1 .and. Pannular_reg>AnnularMovingPressure &
  198. .and. (Annular_closed==0 .or. (Annular_closed==1 .and.PressureGauges(2) <=100.0) .or. (Annular_closed==1 .and.PressureGauges(2)>100.0 .and. Pannular_reg>=AnnularSealingPressure))) then
  199. !write(*,*) 'open 4'
  200. RAM(1)%FourwayValve = 0
  201. Annular_closed=0
  202. !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
  203. p_annular=pa_annular
  204. AnnularLeverOld = AnnularValve
  205. CALL OpenAnnular
  206. Annular_Situation_forTD= 0 ! open - for TD code
  207. RAM(1)%bop_type = 3
  208. !AbopAnnular=758.48 !(in^2)
  209. AbopAnnular=(AnnularPreventerOpen*231)/((IDAnnularBase-ODDrillpipe_inAnnularBase)/2.)
  210. NeededVolumeAnnular=AbopAnnular*(IDAnnularBase-IDAnnular)/(2*231.)
  211. RAM(1)%vdis_bottles=0.
  212. RAM(1)%fvr_air=0.
  213. RAM(1)%vdis_elecp=0.
  214. AnnularIsOpening = .true.
  215. AnnularIsClosing = .false.
  216. !write(*,*) 'open 2'
  217. endif
  218. RAM(1)%First_CloseTimecheck = 0
  219. RAM(1)%First_OpenTimecheck = 0
  220. RAM(1)%time=RAM(1)%time+DeltaT_BOP !overal time (s)
  221. !===================================================
  222. ! BOP
  223. !===================================================
  224. if (Annular_closed==0) then !bop closing
  225. !write(*,*) 'AnnularIsClosing,AnnularIsOpening' , AnnularIsClosing,AnnularIsOpening
  226. call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
  227. endif !bop is closing
  228. !================================================================
  229. if (Annular_closed==1) then
  230. RAM(1)%Q=0
  231. !p_bop=pram_reg
  232. p_annular=pa_annular
  233. endif
  234. RAM(1)%timecounter_ram=RAM(1)%timecounter_ram+1
  235. ! MiddleRamsStatus = IDshearBop
  236. ! UpperRamsStatus = IDPipeRam1
  237. ! LowerRamsStatus = IDPipeRam2
  238. ! AnnularStatus = IDAnnular
  239. ! AccumulatorPressureGauge = p_acc
  240. ! ManifoldPressureGauge= pram_reg
  241. ! AnnularPressureGauge=Pannular_reg
  242. !
  243. !
  244. !
  245. ! WRITE(60,60) RAM(1)%time,RAM(1)%Q,RAM(1)%vdis_tot,p_acc, &
  246. ! pram_reg,Pannular_reg,RAM(1)%p_bop,IDshearBop, &
  247. ! IDPipeRam1,IDPipeRam2,IDAnnular
  248. !60 FORMAT(11(f18.5))
  249. call sleepqq(100)
  250. !CALL CPU_TIME(Annular_EndTime)
  251. !
  252. !
  253. !PUMP(1)%INT_CPU_TIME=IDINT((Annular_EndTime-Annular_StartTime)*1000.)
  254. !PUMP(1)%Dt_ref=IDINT(DeltaT_BOP*1000.)
  255. !
  256. !call sleepqq(PUMP(1)%Dt_ref-PUMP(1)%INT_CPU_TIME)
  257. if (Annular_closed==1) then
  258. ! if ((MiddleRamsValve==1. .and. MiddleRamsFailureMalf==0) .or. (MiddleRamsValve==-1.0 .and. MiddleRamsFailureMalf==0) .or. (LowerRamsValve==1. .and. LowerRamsFailureMalf==0) .or. (LowerRamsValve==-1.0 .and. LowerRamsFailureMalf==0) .or. (UpperRamsValve==1. .and. UpperRamsFailureMalf==0) .or. (UpperRamsValve==-1.0 .and. UpperRamsFailureMalf==0) .or. ChokeLineValve==1. .or. ChokeLineValve==-1.0 .or. KillLineValve==1. .or. KillLineValve==-1.0) then
  259. finished_Annular=1
  260. ! endif
  261. endif
  262. if (IsStopped == .true.) return
  263. end do loop5 !while finished_Annular==0
  264. if ( finished_Annular==1 .and. RAM(1)%Bottles_Charged_MalfActive==.true.) then
  265. call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
  266. call sleepqq(100)
  267. endif
  268. END SUBROUTINE ANNULAR_SUB