- subroutine Pump_OnMode_Solver(Pump_No)
-
- use SimulationVariables
-
- IMPLICIT NONE
- INTEGER :: Pump_No
-
-
-
- data%State%Pump(Pump_No)%Flow_Rate = data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio) ![gpm]
- data%State%Pump(Pump_No)%Max_FlowRate = data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0*data%State%Pump(Pump_No)%MaxSPM ![gpm]
- data%State%Pump(Pump_No)%HorsePower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%StandPipe_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
- !data%State%Pump(Pump_No)%Max_Horsepower = ((data%State%Pump(Pump_No)%Flow_Rate/0.01d0)*data%State%Pump(Pump_No)%Max_Pressure)/(168067.d0*data%State%Pump(Pump_No)%Mech_Efficiency) ![HHP]
- data%State%Pump(Pump_No)%Max_Horsepower = (data%State%Pump(Pump_No)%Flow_Rate*data%State%Pump(Pump_No)%Max_Pressure)/(1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency)
- if ( data%State%Pump(Pump_No)%StandPipe_Pressure>data%State%Pump(Pump_No)%Max_Pressure ) then ! in shart check shavad
- !if ( (data%State%Pump(Pump_No)%StandPipe_Pressure*data%State%Pump(Pump_No)%Flow_Rate)>(1714.d0*data%State%Pump(Pump_No)%Max_Horsepower*data%State%Pump(Pump_No)%Mech_Efficiency) ) then
- data%State%Pump(Pump_No)%Flow_Rate = (1714.d0*data%State%Pump(Pump_No)%Mech_Efficiency*data%State%Pump(Pump_No)%Max_Horsepower)/data%State%Pump(Pump_No)%StandPipe_Pressure ![gpm]
- data%State%Pump(Pump_No)%Speed = ( data%State%Pump(Pump_No)%Flow_Rate/(data%State%Pump(Pump_No)%FlowRatePerSTK*4118.d0*0.01d0) )*data%State%Pump(Pump_No)%Trans_Ratio ![rpm]
- end if
-
- data%State%Pump(Pump_No)%SoundSPM = INT(data%State%Pump(Pump_No)%Speed/data%State%Pump(Pump_No)%Trans_Ratio) ![spm]
-
- If (data%State%Pump(Pump_No)%Flow_Rate>0.d0) Then
- data%State%Pump(Pump_No)%Open_Close = 1
- Else
- data%State%Pump(Pump_No)%Open_Close = 0
- End if
-
-
-
-
-
- end subroutine Pump_OnMode_Solver
|