123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429 |
- SUBROUTINE ANNULAR_SUB1
- use SimulationVariables
- use CBopControlPanel
- use SimulationVariables
- use PressureDisplayVARIABLESModule
- USE CEquipmentsConstants
- USE CBopStackVariables
-
- implicit none
-
- !write(*,*) 'checkpoint 1'
- !=====================================================================
- ! ANNULAR PREVENTER- BOP CAMERON Type U 5000
- ! START CONDITIONS FOR ANNULAR PREVENTER
- !=====================================================================
-
- data%State%RAM(1)%SuccessionCounter = data%State%RAM(1)%SuccessionCounter + 1
-
- if (data%EquipmentControl%BopControlPanel%AnnularValve == 1.0 .and. data%State%Annular%AnnularFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1) then
-
- if (data%State%BopStackInput%AnnularCloseLedMine == LedOn) then
- RETURN
- end if
-
-
- if ( data%State%RAM(1)%SuccessionCounter /= data%State%RAM(1)%SuccessionCounterOld+1 ) then
- data%State%RAM(1)%SuccessionCounter = 0 ! also in starup
- data%State%RAM(1)%SuccessionCounterOld = 0 ! also in starup
- !return
- else
- data%State%RAM(1)%SuccessionCounterOld= data%State%RAM(1)%SuccessionCounter
- endif
-
-
-
- if ( data%State%RAM(1)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then
- !return
-
- data%State%RAM(1)%First_CloseTimecheck= 1
-
- data%EquipmentControl%BopControlPanel%AnnularOpenLED = LedOff
- data%State%BopStackInput%AnnularOpenLedMine = LedOff
- data%EquipmentControl%BopControlPanel%AnnularCloseLED = LedOn !LedBlinking
-
- data%State%RAM(1)%FourwayValve = 1
-
- endif
-
- endif
-
-
- if (data%State%RAM(1)%FourwayValve == 1 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure .and. data%State%Annular%Pannular_reg>data%State%AnnularComputational%AnnularMovingPressure) then ! 1: Open , 0: Close
-
-
- data%State%RAM(1)%FourwayValve = 0
-
-
-
- data%State%Annular%Annular_closed=0
- !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
- data%State%RAM(1)%vdis_tot=0
- data%State%RAM(1)%vdis_bottles=0.
- data%State%RAM(1)%fvr_air=0.
- data%State%RAM(1)%vdis_elecp=0.
- data%State%Pumps%Qiter=7
- data%State%RAM(1)%Qzero=70
- data%State%RAM(1)%Q=data%State%RAM(1)%Qzero
- data%State%RAM(1)%flow=70
- data%State%Annular%tolAnnular=0.0018
- if (data%State%Annular%finished_Annular==1) then
- data%State%Annular%AnnularLeverOld=-1.0
- else
- data%State%Annular%AnnularLeverOld=data%EquipmentControl%BopControlPanel%AnnularValve
- endif
- data%State%Annular%finished_Annular=0
- data%State%Annular%AnnularIsClosing = .true.
- data%State%Annular%AnnularIsOpening = .false.
-
- data%State%RAM(2)%bop_type = 3
- !AbopAnnular=963.1 !(in^2)
- data%State%Annular%AbopAnnular=(data%Configuration%BopStack%AnnularPreventerClose*231.)/((data%State%Annular%IDAnnularBase-data%State%Annular%ODDrillpipe_inAnnularBase)/2.) ! 231 in^3 = 1 gal
- data%State%Annular%NeededVolumeAnnular=data%State%Annular%AbopAnnular*(data%State%Annular%IDAnnularBase-max(data%State%Annular%ODDrillpipe_inAnnular,data%State%Annular%ODDrillpipe_inAnnularBase))/(2.*231) !=17.98 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnularBase=5
- !WRITE(*,*) 'a)NeededVolumeAnnular=' , NeededVolumeAnnular
- !write(*,*) 'close 1'
- endif
-
-
- if (data%EquipmentControl%BopControlPanel%AnnularValve == -1.0 .and. data%State%Annular%AnnularFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1 ) then
-
- if (data%State%BopStackInput%AnnularOpenLedMine == LedOn) then
- RETURN
- end if
-
- !CasingPressure : PressureGauges(2) *****temp conditionssssss
-
- !note: (AnnularSealingPressure) is only for opening while well is pressurised
-
-
- if ( data%State%RAM(1)%SuccessionCounter /= data%State%RAM(1)%SuccessionCounterOld+1 ) then
- data%State%RAM(1)%SuccessionCounter = 0 ! also in starup
- data%State%RAM(1)%SuccessionCounterOld = 0 ! also in starup
- !return
- else
- data%State%RAM(1)%SuccessionCounterOld= data%State%RAM(1)%SuccessionCounter
- endif
-
-
-
- if ( data%State%RAM(1)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then
- !return
-
- data%State%RAM(1)%First_OpenTimecheck= 1
-
- data%EquipmentControl%BopControlPanel%AnnularCloseLED = LedOff !new
- data%State%BopStackInput%AnnularCloseLedMine = LedOff !new
- data%EquipmentControl%BopControlPanel%AnnularOpenLED = LedOn !LedBlinking
-
- data%State%RAM(1)%FourwayValve = 1
-
- endif
-
- endif
-
-
-
-
-
- if (data%State%RAM(1)%FourwayValve == 1 .and. data%State%Annular%Pannular_reg>data%State%AnnularComputational%AnnularMovingPressure .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure &
- .and. (data%State%Annular%Annular_closed==0 .or. (data%State%Annular%Annular_closed==1 .and. data%State%PressureDisplay%PressureGauges(2) <=100.0) .or. (data%State%Annular%Annular_closed==1 .and. data%State%PressureDisplay%PressureGauges(2)>100.0 .and. data%State%Annular%Pannular_reg>=data%State%AnnularComputational%AnnularSealingPressure))) then ! 1: Open , 0: Close
- !write(*,*) 'open 2'
-
- data%State%RAM(1)%FourwayValve = 0
-
-
-
- data%State%Annular%Annular_closed=0
- !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
- data%State%RAM(1)%vdis_tot=0
- data%State%RAM(1)%vdis_bottles=0.
- data%State%RAM(1)%fvr_air=0.
- data%State%RAM(1)%vdis_elecp=0.
- data%State%Pumps%Qiter=7
- data%State%RAM(1)%Qzero=70
- data%State%RAM(1)%Q=data%State%RAM(1)%Qzero
- data%State%RAM(1)%flow=70
- data%State%Annular%tolAnnular=0.0018
-
-
-
- if (data%State%Annular%finished_Annular==1) then
- data%State%Annular%AnnularLeverOld=1.0
- else
- data%State%Annular%AnnularLeverOld=data%EquipmentControl%BopControlPanel%AnnularValve
- endif
- data%State%Annular%finished_Annular=0
- data%State%Annular%AnnularIsOpening = .true.
- data%State%Annular%AnnularIsClosing = .false.
-
-
- !if (AnnularOpenLed == LedOn) then
- ! RETURN
- !end if
-
-
-
- data%State%RAM(1)%bop_type = 3
- !AbopAnnular=758.48 !(in^2)
- data%State%Annular%AbopAnnular=(data%Configuration%BopStack%AnnularPreventerOpen*231)/((data%State%Annular%IDAnnularBase-max(data%State%Annular%ODDrillpipe_inAnnular,data%State%Annular%ODDrillpipe_inAnnularBase))/2.)
- data%State%Annular%NeededVolumeAnnular=data%State%Annular%AbopAnnular*(data%State%Annular%IDAnnularBase-data%State%Annular%ODDrillpipe_inAnnular)/(2.*231) !=14.16 galon for IDAnnularBase=13 5/8 , ODDrillpipe_inAnnular=5
- !write(*,*) 'open 1'
-
- endif
-
- !=====================================================================
-
- if (data%State%Annular%AnnularIsOpening .or. data%State%Annular%AnnularIsClosing .or. data%State%RAM(1)%Bottles_Charged_MalfActive) then
- CALL ANNULAR_SUB2
- end if
-
-
-
-
- END SUBROUTINE ANNULAR_SUB1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- SUBROUTINE ANNULAR_SUB2
- use SimulationVariables
- use PressureDisplayVARIABLESModule
- use CBopControlPanel
- use SimulationVariables
- USE CEquipmentsConstants
- USE CBopStackVariables
- ! use CSimulationVariables
-
- implicit none
-
-
- data%State%Annular%FirstSet= 0
- data%State%AnnularComputational%RamsFirstSet= 0
-
-
- ! loop5: do while (finished_Annular==0)
-
- !write(*,*) 'checkpoint 2'
-
-
- data%State%RAM(1)%SuccessionCounter = data%State%RAM(1)%SuccessionCounter + 1
-
- ! CALL CPU_TIME(Annular_StartTime)
-
- if (data%EquipmentControl%BopControlPanel%AnnularValve == 1.0 .and. data%State%Annular%AnnularLeverOld == -1.0 .and. data%State%Annular%AnnularFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1) then
- if ( data%State%RAM(1)%First_CloseTimecheck == 0 ) then
-
-
-
- if ( data%State%RAM(1)%SuccessionCounter /= data%State%RAM(1)%SuccessionCounterOld+1 ) then
- data%State%RAM(1)%SuccessionCounter = 0 ! also in starup
- data%State%RAM(1)%SuccessionCounterOld = 0 ! also in starup
- !return
- else
- data%State%RAM(1)%SuccessionCounterOld= data%State%RAM(1)%SuccessionCounter
- endif
-
-
-
- if ( data%State%RAM(1)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then
- !return
-
- data%EquipmentControl%BopControlPanel%AnnularOpenLED = LedOff
- data%State%BopStackInput%AnnularOpenLedMine = LedOff
- data%EquipmentControl%BopControlPanel%AnnularCloseLED = LedOn !LedBlinking
-
- data%State%RAM(1)%FourwayValve = 1
-
- endif
-
- endif
- !write(*,*) 'chekkk 1'
-
- endif
-
-
- if (data%State%RAM(1)%FourwayValve == 1 .and. data%State%Annular%Pannular_reg>data%State%AnnularComputational%AnnularMovingPressure .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure) then
- !write(*,*) 'close 4'
-
- data%State%RAM(1)%FourwayValve = 0
-
-
- data%State%Annular%Annular_closed=0
- !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
- data%State%AnnularComputational%p_annular=data%State%AnnularComputational%pa_annular
- data%State%Annular%AnnularLeverOld = data%EquipmentControl%BopControlPanel%AnnularValve
-
- CALL OpenAnnular
- data%State%Annular%Annular_Situation_forTD= 0 ! open - for TD code
- data%State%RAM(1)%bop_type = 3
- !AbopAnnular=963.1 !(in^2)
- data%State%Annular%AbopAnnular=(data%Configuration%BopStack%AnnularPreventerClose*231)/((data%State%Annular%IDAnnularBase-data%State%Annular%ODDrillpipe_inAnnularBase)/2.)
- !write(*,*) 'NeededVolumeShearRams1=',NeededVolumeShearRams
- data%State%Annular%NeededVolumeAnnular=data%State%Annular%AbopAnnular*(data%State%Annular%IDAnnular-max(data%State%Annular%ODDrillpipe_inAnnular,data%State%Annular%ODDrillpipe_inAnnularBase))/(2*231.)
- ! write(*,*) 'NeededVolumeAnnular=',NeededVolumeAnnular
-
- data%State%RAM(1)%vdis_bottles=0.
- data%State%RAM(1)%fvr_air=0.
- data%State%RAM(1)%vdis_elecp=0.
- data%State%Annular%AnnularIsClosing = .true.
- data%State%Annular%AnnularIsOpening = .false.
- !write(*,*) 'close 2'
-
- endif
-
- if (data%EquipmentControl%BopControlPanel%AnnularValve == -1.0 .and. data%State%Annular%AnnularLeverOld == 1.0 .and. data%State%RamLine%P_ACC>data%State%BopStackAcc%acc_MinPressure .and. data%State%Annular%AnnularFailureMalf==0 .and. data%State%BopStackAcc%RigAirMalf==0 .and. data%EquipmentControl%BopControlPanel%AirMasterValve==1 ) then
-
- !CasingPressure : PressureGauges(2) *****temp conditionssssss
-
- !note: (AnnularSealingPressure) is only for opening while well is pressurised
-
- if ( data%State%RAM(1)%First_OpenTimecheck == 0 ) then
-
- if ( data%State%RAM(1)%SuccessionCounter /= data%State%RAM(1)%SuccessionCounterOld+1 ) then
- data%State%RAM(1)%SuccessionCounter = 0 ! also in starup
- data%State%RAM(1)%SuccessionCounterOld = 0 ! also in starup
- !return
- else
- data%State%RAM(1)%SuccessionCounterOld= data%State%RAM(1)%SuccessionCounter
- endif
-
- if ( data%State%RAM(1)%SuccessionCounter >= int(2.5/data%State%RamLine%DeltaT_BOP) ) then
- !return
-
- data%EquipmentControl%BopControlPanel%AnnularCloseLED = LedOff
- data%State%BopStackInput%AnnularCloseLedMine= LedOff
- data%EquipmentControl%BopControlPanel%AnnularOpenLED = LedOn !LedBlinking
-
- data%State%RAM(1)%FourwayValve = 1
-
- endif
-
- endif
- !write(*,*) 'chekkk 2'
-
- endif
-
-
-
- if (data%State%RAM(1)%FourwayValve == 1 .and. data%State%Annular%Pannular_reg>data%State%AnnularComputational%AnnularMovingPressure &
- .and. (data%State%Annular%Annular_closed==0 .or. (data%State%Annular%Annular_closed==1 .and. data%State%PressureDisplay%PressureGauges(2) <=100.0) .or. (data%State%Annular%Annular_closed==1 .and. data%State%PressureDisplay%PressureGauges(2)>100.0 .and. data%State%Annular%Pannular_reg>=data%State%AnnularComputational%AnnularSealingPressure))) then
- !write(*,*) 'open 4'
-
- data%State%RAM(1)%FourwayValve = 0
-
-
- data%State%Annular%Annular_closed=0
- !Annular_closed_withPossibility= Annular_closed * TD_BOPConnectionPossibility(1)
- data%State%AnnularComputational%p_annular=data%State%AnnularComputational%pa_annular
- data%State%Annular%AnnularLeverOld = data%EquipmentControl%BopControlPanel%AnnularValve
-
- CALL OpenAnnular
- data%State%Annular%Annular_Situation_forTD= 0 ! open - for TD code
- data%State%RAM(1)%bop_type = 3
- !AbopAnnular=758.48 !(in^2)
- data%State%Annular%AbopAnnular=(data%Configuration%BopStack%AnnularPreventerOpen*231)/((data%State%Annular%IDAnnularBase-data%State%Annular%ODDrillpipe_inAnnularBase)/2.)
- data%State%Annular%NeededVolumeAnnular=data%State%Annular%AbopAnnular*(data%State%Annular%IDAnnularBase-data%State%Annular%IDAnnular)/(2*231.)
- data%State%RAM(1)%vdis_bottles=0.
- data%State%RAM(1)%fvr_air=0.
- data%State%RAM(1)%vdis_elecp=0.
-
- data%State%Annular%AnnularIsOpening = .true.
- data%State%Annular%AnnularIsClosing = .false.
-
- !write(*,*) 'open 2'
-
- endif
-
-
-
- data%State%RAM(1)%First_CloseTimecheck = 0
- data%State%RAM(1)%First_OpenTimecheck = 0
-
- data%State%RAM(1)%time=data%State%RAM(1)%time+data%State%RamLine%DeltaT_BOP !overal time (s)
-
-
-
-
-
- !===================================================
- ! BOP
- !===================================================
- if (data%State%Annular%Annular_closed==0) then !bop closing
- !write(*,*) 'AnnularIsClosing,AnnularIsOpening' , AnnularIsClosing,AnnularIsOpening
- call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
- endif !bop is closing
- !================================================================
- if (data%State%Annular%Annular_closed==1) then
- data%State%RAM(1)%Q=0
- !p_bop=pram_reg
- data%State%AnnularComputational%p_annular=data%State%AnnularComputational%pa_annular
- endif
-
- data%State%RAM(1)%timecounter_ram=data%State%RAM(1)%timecounter_ram+1
-
-
-
-
-
- ! MiddleRamsStatus = IDshearBop
- ! UpperRamsStatus = IDPipeRam1
- ! LowerRamsStatus = IDPipeRam2
- ! AnnularStatus = IDAnnular
- ! AccumulatorPressureGauge = p_acc
- ! ManifoldPressureGauge= pram_reg
- ! AnnularPressureGauge=Pannular_reg
- !
- !
- !
- ! WRITE(60,60) data%State%RAM(1)%time,data%State%RAM(1)%Q,data%State%RAM(1)%vdis_tot,p_acc, &
- ! pram_reg,Pannular_reg,data%State%RAM(1)%p_bop,IDshearBop, &
- ! IDPipeRam1,IDPipeRam2,IDAnnular
- !60 FORMAT(11(f18.5))
-
-
- ! call sleepqq(100)
-
-
- !CALL CPU_TIME(Annular_EndTime)
- !
- !
- !data%State%Pump(1)%INT_CPU_TIME=IDINT((Annular_EndTime-Annular_StartTime)*1000.)
- !data%State%Pump(1)%Dt_ref=IDINT(DeltaT_BOP*1000.)
- !
- !call sleepqq(data%State%Pump(1)%Dt_ref-data%State%Pump(1)%INT_CPU_TIME)
-
-
-
-
-
- if (data%State%Annular%Annular_closed==1) then
- ! if ((MiddleRamsValve==1. .and. MiddleRamsFailureMalf==0) .or. (MiddleRamsValve==-1.0 .and. MiddleRamsFailureMalf==0) .or. (LowerRamsValve==1. .and. LowerRamsFailureMalf==0) .or. (LowerRamsValve==-1.0 .and. LowerRamsFailureMalf==0) .or. (UpperRamsValve==1. .and. UpperRamsFailureMalf==0) .or. (UpperRamsValve==-1.0 .and. UpperRamsFailureMalf==0) .or. ChokeLineValve==1. .or. ChokeLineValve==-1.0 .or. KillLineValve==1. .or. KillLineValve==-1.0) then
- data%State%Annular%finished_Annular=1
- ! endif
- endif
-
- ! if (IsStopped == .true.) return
-
-
- ! end do loop5 !while finished_Annular==0
-
-
-
-
-
- if ( data%State%Annular%finished_Annular==1 .and. data%State%RAM(1)%Bottles_Charged_MalfActive==.true.) then
- call bop_codeAnnular(1) !ramtype=4 1=RNUMBER
- ! call sleepqq(100)
- endif
-
- END SUBROUTINE ANNULAR_SUB2
|